Description
In-Situ SE2000 Hermit 2000 Environmental Data Logger RS232C For Parts Repair
The SE2000 Hermit 2000 is a portable environmental data logger designed for field-based groundwater monitoring and sensor data acquisition. It records and stores environmental measurements via multiple sensor ports and communicates data through RS232C serial interface.
Specifications & What's Included
- Brand: In-Situ Inc.; Model: SE2000
- Interface: RS232C (8-pin circular connector)
- Display: LCD with F1-F4 function keys and numeric keypad
- Power: External 120V AC supply (5VDC, 500mA output)
- Multiple sensor ports on top panel with EXT PWR ALARM port
- Includes: RS232C data cable and external power supply
- USA manufactured
Applications
The SE2000 was used in groundwater monitoring networks and environmental data collection systems. It interfaces with In-Situ sensor probes for continuous or scheduled measurement of water quality parameters. Typical deployment involved field sites requiring automated data logging with periodic download via RS232C connection to computer systems.
This In-Situ SE2000 Hermit 2000 Environmental Data Logger is being sold as-is for parts or repair. The internal battery (Electrochem Industries Part No. AVT-3000-12A, BCX72, DD size) is bad and the unit will not operate on internal power alone — it requires an external power supply to function. The unit has not been bench-tested and no functionality is guaranteed. The enclosure shows moderate wear including paint chips, scuffing, and surface marks on the rear and sides, consistent with field use. Importantly, one of the included cables shows exposed and frayed wiring at the connector boot and should be inspected before any use. Included with the unit are an RS232C data cable (8-pin circular to DB9 female) and an external power supply (120V AC / 5VDC 500mA). Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
In-Situ Inc. |
Model: |
SE2000 |
MPN: |
SE2000 |
Type: |
Environmental Data Logger |
SKU: |
47432 |
Condition: |
As-Is / For Parts or Not Working |
Seller Notes: |
Includes RS232C data cable and external power supply. Internal battery is bad. |
Interface Type: |
RS232C |
Display Type: |
LCD |
Input/Output Ports: |
RS232C (8-pin circular), multiple sensor ports on top panel |
Power Source: |
External power supply (internal battery non-functional) |
Internal Battery: |
Electrochem Ind. AVT-3000-12A, BCX72, DD Size (bad/depleted) |
External Power Supply: |
120V AC, 60Hz, 18W input; 5VDC, 500mA output (included) |
Form Factor: |
Portable / Field Instrument |
Country/Region of Manufacture: |
United States |
Application: |
Environmental monitoring, groundwater data acquisition |
Compatible With: |
In-Situ groundwater sensors and probes |
Front Panel Controls: |
F1-F4 function keys, numeric keypad, SCAN, STOP, START/STEP, DUMP DATA, VIEW DATA |
Alarm Output: |
EXT PWR ALARM port on top panel |
Condition Notes: |
In-Situ SE2000 Hermit 2000 Environmental Data Logger sold as-is for parts/repair. Internal battery (Electrochem AVT-3000-12A) is bad; external power only. Not bench-tested. Includes RS232C cable and external power supply. Cable shows frayed wiring. |