In-Situ

In-Situ HERMIT SE 1000C Environmental Data Logger RS-232 4-20mA For Parts

(No reviews yet) Write a Review
SKU:
47544
MPN:
SE 1000C
Condition:
Used
Availability:
Usually ships within 1-2 business days.
Weight:
15.00 LBS
Shipping:
Calculated at Checkout
  • In-Situ HERMIT SE 1000C environmental data logger open case showing front panel controls, LCD display, RS-232 cable, and interior documentation label
  • In-Situ SE 1000C HERMIT data logger LCD display showing readout, RS232C label visible at top right of front panel
  • In-Situ HERMIT SE 1000C front panel label showing model number SE 1000C, In-Situ Inc. branding, and Handle With Care impact warning sticker
  • In-Situ HERMIT SE 1000C portable data logger closed case rear view showing two latch clasps, In-Situ Inc. logo, and yellow transducer port with chain cap — labeled THIS IS CLEANED EQUIPMENT
  • In-Situ HERMIT SE 1000C bottom view showing four yellow locking transducer interface ports with chain-tethered caps
  • In-Situ HERMIT SE 1000C right-side view showing two hinge clasps and one yellow transducer port with chain cap
  • In-Situ HERMIT SE 1000C open case side-angle view showing front panel LCD, push-button controls, transducer port, and yellow warning label on case interior
  • Included transducer interface cable with 5-pin circular locking connector for In-Situ SE 1000C data logger
  • Included RS-232 cable with DB-9 female connector for In-Situ HERMIT SE 1000C data logger
$95.00
Was: $200.00
Current Stock: 1

Sold Out

Description

In-Situ HERMIT SE 1000C Environmental Data Logger RS-232 4-20mA For Parts

The In-Situ HERMIT SE 1000C is a portable, self-contained environmental data logger designed for field measurement and recording of water-quality and environmental parameters. Housed in a rugged blue carry case with locking latches, it interfaces with In-Situ's standard transducers as well as most industry-standard 4-20 mA current-loop transducers through four locking yellow ports on the base of the unit. Recorded data can be viewed on the built-in LCD, printed via an optional field printer, or downloaded to a personal computer through the built-in RS-232C serial interface. This unit is being sold AS-IS for parts or repair due to a depleted on-board battery.

Specifications & What's Included

  • Manufacturer: In-Situ Inc.
  • Product Series: HERMIT
  • Model: SE 1000C (SE1000C)
  • Type: Portable Environmental Data Logger
  • Measured Parameters: Level, pressure, temperature, conductivity, and pH
  • Transducer Interface: In-Situ standard transducers; also supports industry-standard 4-20 mA (milliampere) current-loop transducers
  • Transducer Ports: 4 × yellow locking circular ports with chain-tethered caps (bottom of unit)
  • Data Storage: 32K bytes (32,768 characters) non-volatile memory
  • Display: Built-in LCD on front panel
  • Data Output: Built-in RS-232C serial interface; optional field printer output
  • RS-232 Connector: DB-9 female (cable included)
  • Transducer Cable: 5-pin circular locking connector (cable included)
  • Form Factor: Portable carry case with handle, latches, and hinges
  • Known Issue: On-board battery depleted — must be replaced before use
  • Includes: RS-232 DB-9 cable and 5-pin circular transducer interface cable

Applications

The In-Situ HERMIT SE 1000C was designed for environmental field monitoring — primarily groundwater quality assessment, surface water monitoring, and general environmental compliance work. Units like this were deployed at remediation sites, municipal water systems, industrial facilities, and environmental consulting projects where portable, battery-powered data logging was needed in remote or in-well locations. The 4-20 mA current-loop input made the logger compatible with a wide range of third-party transducers measuring parameters such as water level, pressure, temperature, conductivity, and pH, making it a versatile platform across environmental disciplines. The built-in RS-232C port allowed field technicians to offload logged data directly to a laptop for analysis and reporting. The HERMIT logger dates from the late 1980s to early 1990s era of portable environmental instrumentation, when non-volatile solid-state data storage was replacing paper chart recorders for field data collection. These units are still sought by technicians maintaining legacy monitoring installations and by environmental instrumentation collectors.

Condition: For Parts or Not Working
This In-Situ HERMIT SE 1000C Environmental Data Logger is being sold AS-IS for parts or repair. The on-board battery is depleted and will need to be replaced before the unit can be used. Cosmetically, the blue carry case is in good shape with light surface wear and scuffing consistent with field use; the latches, hinges, and locking clasps are all intact. The front panel controls and LCD are present and undamaged. Four yellow locking transducer ports on the bottom are present with their chain-tethered caps. Both the RS-232 DB-9 cable and the 5-pin circular transducer interface cable are included. No functionality is guaranteed. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
In-Situ Inc.
Model:
SE 1000C
MPN:
SE1000C
Product Name / Series:
HERMIT
Type:
Environmental Data Logger
SKU:
47544
Condition:
As-Is / For Parts or Not Working
Seller Notes:
Includes RS-232 cable and transducer interface cable. Battery depleted — sold for parts.
Form Factor:
Portable / Handheld Case
Interface Type:
RS-232C (DB-9 female)
Transducer Interface:
4-20 mA current loop; 4 yellow locking ports
Data Storage:
32K bytes (32,768 characters) non-volatile
Display Type:
LCD
Measured Parameters:
Level, pressure, temperature, conductivity, pH
Compatible Transducers:
In-Situ standard transducers; 4-20 mA industry standard
Country/Region of Manufacture:
United States
Application:
Environmental field monitoring, groundwater, water quality
Known Issues:
On-board battery depleted and requires replacement
Condition Notes:
In-Situ HERMIT SE 1000C Environmental Data Logger sold AS-IS for parts/repair. On-board battery is depleted and must be replaced. Cosmetically good. Includes RS-232 and transducer cables. Not guaranteed functional.