Endress-Hauser

Endress-Hauser

  • Endress+Hauser CM42 Liquiline M two-wire transmitter front view showing LCD display, navigation buttons, rotary selector, and Memosens sensor port with conduit Endress+Hauser CM42 Liquiline M transmitter rear and top view showing blue housing with conduit and mounting plate attached

    Endress+Hauser CM42 CM42-MPA001EAE00 Liquiline M Two-Wire Transmitter HART

    Endress-Hauser

    $475.00
    Was: $950.00
    Endress+Hauser CM42 CM42-MPA001EAE00 Liquiline M Two-Wire Transmitter HARTTwo-wire process transmitter for liquid analysis and Memosens sensor measurement. Outputs 3.6–22 mA HART signal over a single...
    52927
    SKU:
    52927
    Availability:
    Usually ships within 1–2 business days.
    Weight:
    7.00 LBS
    Brand:
    Endress+Hauser
    Model:
    CM42
    MPN:
    CM42-MPA001EAE00
    Secondary Model:
    CM42-MPA001EAE00
    Type:
    Two-Wire Process Transmitter
    SKU:
    52927
    Device Version:
    02.01.00
    Series:
    Liquiline M
    Measurement Type:
    Liquid Analysis / Memosens Sensor
    Output Signal:
    3.6–22 mA (HART)
    Protocol:
    HART, FOUNDATION Fieldbus, PROFIBUS PA
    Max Supply Voltage:
    30 V DC
    Max Power Consumption:
    88 mW
    Enclosure Rating:
    IP66/67
    Ambient Temperature Range:
    -20°C and above (per label)
    Hazardous Area Rating:
    Class I Div 1 GP A,B,C,D; Class I Zone 0 GP IIC T6
    Additional Approval:
    Class I Div 2 GP A,B,C,D
    Control Drawing:
    139680
    Pollution Degree:
    3
    Form Factor:
    Field-Mount / Wall-Mount
    Interface Type:
    HART / FOUNDATION Fieldbus / PROFIBUS PA
    Seller Notes:
    Includes mounting plate. No sensor, sensor cable, or weather protection cover.
    Condition:
    Used – Pulled from Working Environment
    Country/Region of Manufacture:
    Germany
    Condition Notes:
    Endress+Hauser CM42 Liquiline M two-wire transmitter. Inspected, in good used condition. Pulled from a working process environment. Includes mounting plate. No sensor, sensor cable, or weather protection cover.
    California Prop 65 Warning:
    WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov
    $475.00
    Was: $950.00
  • Endress+Hauser Promag 10 electromagnetic flowmeter transmitter head and Promag W sensor with connecting cable – three-quarter front view Endress+Hauser Promag 10 flowmeter showing rating plate label on transmitter body and sensor with coaxial cable connectors

    Endress+Hauser Promag 10 10W2F Electromagnetic Flowmeter HART I-Out Pulse Out

    Endress-Hauser

    $425.00
    Was: $850.00
    Endress+Hauser Promag 10 10W2F Electromagnetic Flowmeter HART I-Out Pulse OutThe Endress+Hauser Promag 10 is a two-component electromagnetic flowmeter system consisting of the Promag 10 transmitter...
    52323
    SKU:
    52323
    Availability:
    Usually ships within 1-2 business days.
    Weight:
    16.00 LBS
    Brand:
    Endress+Hauser
    Model:
    Promag 10
    MPN:
    10W2F
    Order Code:
    10W2F-ULGA1RG2B5AA
    Type:
    Electromagnetic Flowmeter (Magmeter)
    SKU:
    52323
    Seller Notes:
    Includes transmitter head and Promag W sensor with connecting cable.
    Country/Region of Manufacture:
    Germany
    Form Factor:
    Remote Mount (Transmitter + Sensor)
    Power Requirements:
    11-40VDC / 20-28VAC, 50-60Hz, 8VA/6W
    Output Type:
    I-Out (HART 4-20mA), Pulse Output
    Communication Protocol:
    HART
    Enclosure Rating:
    NEMA/Type 4X
    Hazardous Area Classification:
    FM: CL I, DIV.2, GP ABCD; CL II, DIV.1
    Temperature Range:
    -20°C to +60°C (-4°F to +140°F)
    Display:
    LCD with 3-button keypad (Esc, -, +, E)
    Certifications:
    CE, FM Approved, CSA, NI2895
    Approvals:
    Dust-Ignitionproof CL II DIV.1; CL I Zone 2 IIC T4A
    Application:
    Water and wastewater flow measurement
    Condition:
    Used – Pulled from Working Environment
    Condition Notes:
    Endress+Hauser Promag 10 10W2F electromagnetic flowmeter in good used condition. Pulled from a working environment where it was in active service. Light surface wear on housing. LCD and keypad intact. Please contact us with any questions.
    California Prop 65 Warning:
    WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov
    $425.00
    Was: $850.00
  • Endress+Hauser PMD55 Deltabar differential pressure transmitter – front view showing blue housing, LCD display, and stainless steel manifold block Endress+Hauser PMD55 – left-side view showing blue transmitter body, stainless process manifold, and conduit entry fitting

    Endress+Hauser PMD55 Deltabar Differential Pressure Transmitter 0-200 PSI HART

    Endress-Hauser

    $600.00
    Was: $1,200.00
    Endress+Hauser PMD55 Deltabar Differential Pressure Transmitter 0-200 PSI HARTField-mounted differential pressure transmitter for process and environmental monitoring. Measures pressure differential...
    52318
    SKU:
    52318
    Availability:
    Usually ships within 1–2 business days.
    Weight:
    14.00 LBS
    Brand:
    Endress+Hauser
    Model:
    PMD55
    MPN:
    PMD55-ED80/101
    Secondary Model:
    PMD55-CD21BD67LGJHAJA1A+AAF
    Material Number:
    71082634
    Ident:
    033FK
    SKU:
    52318
    Type:
    Differential Pressure Transmitter
    Condition:
    Used – Pulled from Working Environment
    Output Signal:
    4–20mA HART
    Pressure Range:
    0–200 PSI
    Calibration/Adjustment Range:
    0...200 PSI
    Span:
    12/240 PSI
    Supply Voltage:
    11.5...45V DC
    Sensor Type:
    Piezoresistive, welded metallic membrane
    Safety Integrity Level:
    SIL2 per IEC 61508 / IEC 61511
    Display:
    Integrated LCD display with keypad
    Enclosure Type:
    TYPE4X/6P
    Certifications:
    CSA, CE, Ex (intrinsically safe)
    Measurement Medium:
    Liquids, vapors, gases
    Application:
    Process and environmental differential pressure measurement
    Country/Region of Manufacture:
    USA (Endress+Hauser, Greenwood, IN)
    Form Factor:
    Field-mount transmitter
    Seller Notes:
    Unit only; no accessories. Pulled from a facility that closed operations.
    Condition Notes:
    Endress+Hauser PMD55 Deltabar DP transmitter inspected and in good used condition. Pulled from a facility that closed operations. Light service wear; LCD window clear. No damage noted. Contact us with questions.
    California Prop 65 Warning:
    WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov
    $600.00
    Was: $1,200.00