Hybaid MAXI 14 Hybridization Oven 35mm Carousel Ambient +8 to 85°C 115V 250W
The Hybaid MAXI 14 is a benchtop hybridization oven designed for molecular biology applications requiring controlled incubation with continuous sample rotation. It accepts a 14-slot carousel that holds standard 35mm hybridization bottles and maintains stable temperatures across a wide range while rotating samples at selectable speeds. This unit rotates and heats normally; see condition notes regarding the dual-action shaking platform.
Specifications & What's Included
- Brand: Hybaid
- Model: MAXI 14
- Temperature range: Ambient +8°C to 85°C
- Temperature controller: CAL 3200 digital controller (front panel, green LED display)
- Carousel capacity: 14 slots — accepts 35mm hybridization bottles
- Carousel speed: 5–15 RPM (front-panel dial)
- Shaking action: Dual action — linear or orbital (per manual; see condition notes)
- Power: 115 VAC, 60 Hz, 250W, 2.75A
- Internal chamber dimensions: 14" W × 12" D × 20" H
- External dimensions: 18" W × 19" D × 27" H
- Front panel controls: carousel speed dial, two rocker switches, shaking mode knob, power rocker switch
- Chamber: stainless steel interior with glass-windowed door
- Drive coupling: stainless shaft coupling on interior rear wall
- Includes: 14-slot 35mm carousel with metal end-plates and spring bottle clips
Applications
Hybridization ovens are standard equipment in molecular biology labs for nucleic acid hybridization procedures including Southern blotting, Northern blotting, and DNA/RNA probe hybridization. Samples in hybridization bottles are loaded onto the rotating carousel, which keeps probe solution in continuous contact with the membrane throughout the incubation period — eliminating the uneven hybridization that results from static incubation. The MAXI 14's wide temperature range (ambient +8°C to 85°C) covers the full spectrum of hybridization protocols from low-stringency to high-stringency conditions, as well as pre-hybridization blocking steps and post-hybridization wash cycles. The Hybaid MAXI series was a widely used platform in academic and commercial molecular biology labs from the 1990s onward, and the 35mm carousel format remains a recognized standard for hybridization bottle-based work.
This Hybaid MAXI 14 Hybridization Oven is in used condition and has been inspected at our facility. The carousel rotates and the unit heats normally. There is some cosmetic damage to the temperature controller buttons on the front panel — they show wear and minor physical damage, but they remain functional. The manual describes a dual-action shaking platform (linear or orbital mode), but we were unable to confirm this motion during our testing; we cannot determine whether we tested this feature correctly or whether it is non-functional. Buyers interested in the dual-action shaking feature should factor this uncertainty into their purchase decision. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
Hybaid |
Model: |
MAXI 14 |
MPN: |
MAXI 14 |
Type: |
Hybridization Oven |
SKU: |
48535 |
Temperature Range: |
Ambient +8°C to 85°C |
Carousel Capacity: |
14 slots — accepts 35mm bottles |
Carousel Speed: |
5–15 RPM |
Power Requirements: |
115 VAC, 60 Hz, 250W, 2.75A |
Voltage: |
115V AC |
Wattage: |
250W |
Frequency: |
60 Hz |
Internal Dimensions: |
14"W x 12"D x 20"H |
External Dimensions: |
18"W x 19"D x 27"H |
Shaking Action: |
Dual action — linear or orbital (per manual) |
Form Factor: |
Benchtop |
Application: |
Molecular biology hybridization, Southern/Northern blot |
Country/Region of Manufacture: |
United Kingdom |
Seller Notes: |
Includes 14-slot 35mm carousel; no manual included |
Condition Notes: |
This Hybaid MAXI 14 Hybridization Oven rotates and heats normally. Temperature controller buttons show cosmetic damage but remain functional. Dual-action shaking platform (per manual) could not be confirmed during testing. |
California Prop 65 Warning: |
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov |