Description
Wavetek 1045 RF Power Meter 1 MHz to 26.5 GHz GPIB 4-Channel Benchtop
The Wavetek 1045 is a benchtop RF power meter covering 1 MHz to 26.5 GHz. It accepts up to four detector probes simultaneously via rear-panel BNC inputs and presents readings on a bright LED digital display as well as an analog meter for coarse relative-power indication in linear modes. Front-panel controls select measurement mode, noise filter, and CAL factor offset, while a GPIB (IEEE-488) interface enables full remote operation in automated test systems.
Specifications & What's Included
- Manufacturer: Wavetek
- Model: 1045
- Frequency range: 1 MHz to 26.5 GHz
- Number of detector channels: 4 (rear-panel BNC inputs labeled 1–4 / CAL 2, 3, 6)
- Display: LED digital readout (6-digit) + analog relative power meter (Coarse Zero / Linear modes)
- Measurement modes: Linear Manual, Linear Auto, Log, Coarse Zero, CAL, dBm Manual Ref, dB Offset, dB Auto Ref
- CAL output: rear-panel BNC (–15 dBm / –10 dBm)
- Additional rear outputs: RF Blanking Output, Ratio/Marker Output, Analog Output
- Additional rear inputs: Trigger Input, Interface Input/Output
- Remote interface: GPIB (IEEE-488) — configurable Listen Address, Talk Address, and Service Request via rear-panel GPIB Internal Switch Status label
- Front-panel controls: Power On, Noise Filter (On/Off), New Data indicator, Remote indicator, Mode selector, CAL Factor –dB rotary knob, Detector selector knob, Fine Zero control
- Power input: IEC inlet with fuse drawer; 48–480 Hz (voltage selectable — consult manual)
- Options installed: Opt. 01/05 (per rear-panel label)
- Form factor: benchtop (also rack-mountable)
- Included: unit only — no detector probes, cables, or manual
Applications
The Wavetek 1045 belongs to a class of multi-channel RF power meters widely used in RF and microwave laboratory environments from the 1970s through the 1990s. Instruments of this type measure the absolute or relative power level of an RF or microwave signal by connecting a calibrated thermocouple or diode detector probe to the signal under test and displaying the result in dBm or watts. The 1045's four-channel architecture and GPIB interface made it well suited for automated test systems — common in production testing of RF amplifiers, antennas, filters, and signal generators across the 1 MHz to 26.5 GHz range. The GPIB bus (IEEE-488) was the dominant instrument-control interface of its era, and the 1045 integrates cleanly into HP/Agilent-style ATE racks alongside spectrum analyzers, signal generators, and network analyzers. Today these meters continue to see use in legacy lab environments, educational RF labs, and by RF engineers maintaining older test benches where compatible Wavetek detector probes are available.
This Wavetek 1045 RF Power Meter has been inspected and appears to be in good used condition. It was pulled from a working environment where it was previously in service. The front panel, including the LED display and analog meter, shows normal wear consistent with bench use. The chassis shows scuffing and minor marks across the top and sides. All front-panel controls — Mode switches, Noise Filter, CAL Factor knob, and Detector selector — are present and intact. Rear-panel connectors including the four detector input BNCs, GPIB interface port, CAL output, RF blanking output, analog output, and IEC power inlet all appear undamaged. A Micro Quality Cal calibration sticker is visible on the front panel, along with a HAPTECH asset tag. No detector probes, cables, or manual are included. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
Wavetek |
Model: |
1045 |
MPN: |
1045 |
Type: |
RF Power Meter |
SKU: |
44867 |
Frequency Range: |
1 MHz to 26.5 GHz |
Number of Channels: |
4 |
Interface: |
GPIB (IEEE-488) |
Display Type: |
LED digital readout + analog meter |
Measurement Modes: |
Linear Manual, Linear Auto, Log, Coarse Zero, Cal, dB Manual Ref, dB Offset, dB Auto Ref |
Outputs: |
CAL Output, RF Blanking Output, Ratio/Marker Output, Analog Output |
Inputs: |
4x Detector Input (BNC), Trigger Input, Interface I/O |
Power Input: |
48–480 Hz (selectable voltage — see manual), IEC inlet with fuse |
Form Factor: |
Benchtop / Rackmount |
Options: |
Opt. 01/05 (label visible on rear panel) |
CAL Factor Adjustment: |
Rotary CAL Factor –dB control on front panel |
Noise Filter: |
On/Off switch on front panel |
Remote Operation: |
Yes — GPIB (IEEE-488) with configurable Listen/Talk address |
Seller Notes: |
Unit only — no detector probes, cables, or manual included. |
Country/Region of Manufacture: |
United States |
Condition Notes: |
This Wavetek 1045 RF Power Meter has been inspected and is in good used condition, pulled from a working environment. Front-panel controls and rear connectors appear intact. Normal cosmetic wear on chassis. No probes, cables, or manual included. |
California Prop 65 Warning: |
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov |