  • Radiometer America ABL 500 Blood Gas Analyzer front view with printer, color monitor, keyboard, and numbered sample inlet ports
  • Radiometer ABL 500 display screen showing startup system information: Power On, December 10 2003, remaining startup time 15 minutes, temperature 9.92°C
  • Radiometer ABL 500 printer output showing error messages: GAS ERROR A, RINSE ERROR A, SBS ERROR A, and DISK ERROR with descriptions
  • Radiometer America and Radiometer Copenhagen manufacturer labels on rear panel with serial number plate ABL500 111R22N15
  • Radiometer ABL 500 Blood Gas Analyzer rear view showing power connections, serial data ports, ventilation grille, and cabling
$2,700.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Radiometer America ABL 500 Blood Gas Analyzer pH pCO2 pO2 Electrolytes Clinical

The Radiometer America ABL 500 is a benchtop clinical blood gas analyzer designed for comprehensive arterial blood analysis in hospital and clinical laboratory settings. It measures blood gases (pH, pCO2, pO2), electrolytes, oximetry parameters, and metabolites from a single whole-blood sample. The system integrates a color monitor display, built-in thermal printer, numeric keypad, and full keyboard in a self-contained floor-standing configuration.

Specifications & What's Included

  • Manufacturer: Radiometer America Inc. (Radiometer A/S, Copenhagen, Denmark)
  • Model: ABL 500 (ABL500)
  • Measurement parameters: pH, pCO2, pO2 (blood gases); electrolytes; oximetry; metabolites
  • Configurable parameter profiles — select combinations of blood gas, oximetry, electrolyte, and metabolite measurements
  • Automatic level detection and temperature correction
  • Automated QC procedures with automatic calculation of control statistics
  • Remote monitoring compatible with RADIANCE STAT analyzer management system software
  • Integrated color CRT monitor/display with function key interface
  • Integrated printer module (thermal/dot-matrix) for results and error logs
  • Numbered sample inlet ports (positions 1–6 visible on front)
  • Full-travel QWERTY keyboard included
  • Rear panel: serial/data ports (DB9), power connections, ventilation
  • Form factor: benchtop/floor-standing, two-tier configuration

Applications

The ABL 500 is designed for clinical blood gas testing in hospital intensive care units, emergency departments, operating rooms, and core clinical laboratories. Blood gas analyzers in this class measure the partial pressures of oxygen and carbon dioxide, pH, and related parameters directly from whole arterial blood samples, providing critical data for monitoring a patient's respiratory and metabolic status. The ABL series from Radiometer — a Danish company with a long history in blood gas instrumentation dating to the 1950s — was widely deployed in mid-to-large hospital laboratories through the 1990s and early 2000s. The ABL 500 in particular supports multiple parameter configurations, allowing a single instrument to serve both point-of-care and core lab roles. Today, retired ABL 500 units are sought by clinical engineering programs, biomedical training facilities, international hospitals, and parts suppliers.

Condition: Used
This Radiometer America ABL 500 Blood Gas Analyzer is a used clinical instrument being sold as-is. The unit does power on — the display screen shows the ABL500 startup screen with system information active. However, the built-in printer has outputted a report showing several active errors logged in December 2003: GAS ERROR A (CO₂ pressure too low), RINSE ERROR A (no rinse solution detected), SBS ERROR A (no salt-bridge solution detected), and a DISK ERROR. These errors appear to be consumable and maintenance-related rather than hardware failures, but the unit has not been tested or verified at our facility beyond what is visible in the photos. The exterior shows normal wear consistent with clinical use. The system includes the main analyzer unit, integrated printer module, color monitor/display, numeric keypad, and full-travel keyboard. Please review all photos carefully and contact us with any questions before purchasing.
Medical Device Disclosure
Thanks for your interest. Recycled Goods Inc., Ventura, CA.

FDA Regulation and Certification: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not purchase this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping.

Upon receipt, it is the BUYER'S responsibility to have this instrument checked and certified for use by a qualified Technician prior to placing it into use or service.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Radiometer
Model:
ABL 500
MPN:
ABL500
Type:
Blood Gas Analyzer
SKU:
14588
Seller Notes:
Analyzer, printer module, monitor/display, keyboard, and sample inlet assembly included.
Country/Region of Manufacture:
Denmark
Form Factor:
Benchtop / Floor-Standing
Measurements:
pH, pCO2, pO2, Electrolytes, Oximetry, Metabolites
Parameters:
Blood gases, oximetry, electrolytes, metabolites
Remote Monitoring:
RADIANCE STAT analyzer management system compatible
Display:
Color CRT monitor with touchscreen-style function keys
Printer:
Integrated thermal/dot-matrix printer
Application:
Clinical laboratory, hospital, point-of-care blood gas testing
Compatible With:
RADIANCE STAT management software
Condition Notes:
Radiometer America ABL 500 Blood Gas Analyzer powers on (startup screen visible). Logged errors include GAS ERROR A, RINSE ERROR A, SBS ERROR A, and DISK ERROR — likely consumable/maintenance issues. Not bench-tested at our facility. Sold as-is.