  • Origen IGEN M-Series M8 Toxin Analyzer full unit on rolling wire cart with two reagent containers on lower shelf – front-left view
  • Origen IGEN M-Series M8 Toxin Analyzer rear panel showing power switch, controls, and two large reagent jugs on cart lower shelf
  • Origen M-Series M8 rating plate label showing model M8-1003-0950, revision D, 100-120/200-230V 50-60Hz, 10A/5A
  • Origen M-Series ORI-CLEAN Plus Solution 5-gallon reagent container label – IGEN International, Gaithersburg MD
  • Origen M-Series ORI-GLO Plus Solution 5-gallon reagent container label – IGEN International, Lot 37372
  • M-Series M8 Analyzer Reagent 3 Container label showing ProClin 150 contents and IGEN International contact information
  • Origen IGEN M-Series M8 Analyzer integrated QWERTY keyboard mounted on front housing – top-down view
  • Origen M-Series M8 internal 3.5-inch floppy disk drive with IGEN International instrument serial number card
  • Origen IGEN M-Series M8 Analyzer reagent port panel showing Level Detect DB15 connector and Reagent 1, 2, 3, and Waste fittings
  • Origen IGEN M-Series M8 rear I/O panel showing COM A, COM B, Video, Printer Port, Network, and Modem connectors with cooling fan
  • Origen IGEN M-Series M8 Analyzer color LCD display screen showing graphical test output – front-on view
  • Origen IGEN M-Series M8 rear cooling fan module – NMB brushless DC motor close-up
  • Origen IGEN M-Series M8 Analyzer laser compartment open showing Class 1/Class 2 laser warning labels and optical assembly
  • ORIGEN Technology Instrumentation Training Material binder – included with analyzer
  • M-Series M8 Analyzer Operation Manual binder for Software Version 1.9 – included with unit
  • M-Series M8/384 Analyzers Operation Manual binder for Software Version 1.9 – second manual included with unit
$1,500.00
Was: $3,000.00
Current Stock: 1

Sold Out

Description

Origen IGEN M-Series M8 Toxin Analyzer M8-1003-0950 100-120/200-230V w/ Manual

The Origen IGEN M-Series M8 is a benchtop electrochemiluminescence (ECL) detection instrument developed by IGEN International for rapid analysis of food-borne, water-borne, and environmental toxins. It uses ECL — a technology in which labeled reagents emit light when electrically stimulated at an electrode surface — to detect target analytes at very low concentrations. The M8 processes up to 8 samples per run and is controlled through an integrated color LCD touchscreen and a built-in QWERTY keyboard running proprietary software. This unit (MPN M8-1003-0950, Rev D) is sold as-is for parts or repair and has not been tested at our facility.

Specifications & What's Included

  • Manufacturer: IGEN International, Inc. (Gaithersburg, MD) — marketed under the Origen brand
  • Model: M-Series M8
  • Part Number / MPN: M8-1003-0950
  • Revision: D
  • Power Input: 100-120V / 200-230V AC, 50-60Hz (dual voltage)
  • Current: 10A (at 100-120V) / 5A (at 200-230V)
  • Display: Integrated color LCD touchscreen (front-facing)
  • Keyboard: Integrated compact QWERTY keyboard (front housing)
  • Storage: Internal 3.5-inch floppy disk drive
  • Laser: Class 1 Laser Product per IEC 60825-1: 1993+A1+A2; Class 2 radiation when open — do not stare into beam
  • Reagent Connections: Reagent 1, Reagent 2, Reagent 3, and Waste ports with level-detect (DB15 connector)
  • Rear I/O: COM A (DB9), COM B (DB9), Video (DB9), Printer Port (DB25), Network (RJ45), Modem (RJ11)
  • Cooling: NMB brushless DC fan module (rear exhaust)
  • Form Factor: Benchtop instrument; mounted on rolling wire cart (included)
  • Compatible Reagents: Origen ORI-CLEAN Plus Solution, Origen ORI-GLO Plus Solution (M-Series)
  • Included: Two 5-gallon Origen M-Series reagent containers (ORI-CLEAN Plus and ORI-GLO Plus), one Reagent 3 container
  • Included: ORIGEN Technology Instrumentation Training Material binder
  • Included: M-Series M8 Analyzer Operation Manual (for Software Version 1.9)
  • Included: M-Series M8/384 Analyzers Operation Manual (for Software Version 1.9)
  • Compatible Models (per manuals): M-Series M8 and M-Series M8/384

Applications

The IGEN M-Series platform was designed for laboratory testing of food safety, water quality, and environmental samples, specifically for the detection of toxins, pathogens, and other target analytes at trace concentrations using electrochemiluminescence. ECL-based analyzers like the M8 are used in food and beverage quality control labs, environmental monitoring programs, agricultural testing, and research settings where highly sensitive, quantitative detection of multiple analytes per run is required. The technology was originally developed by IGEN International in the 1990s and gained wide adoption in food safety and bioanalytical research; Meso Scale Diagnostics (MSD) later acquired and further commercialized ECL detection technology. The M8 model, with its integrated touchscreen, floppy-drive data storage, and multi-reagent fluid handling system, is characteristic of late-1990s to early-2000s laboratory instrument design. Labs maintaining legacy IGEN-platform methods or sourcing the instrument for parts, repair, or as a reference unit are the primary buyers for this type of equipment.

Condition: For Parts or Not Working
This Origen IGEN M-Series M8 Toxin Analyzer (MPN M8-1003-0950) has been visually inspected and appears to be in good cosmetic condition overall, but has not been tested at our facility and is being sold as-is for parts or repair. No functionality is guaranteed. The instrument is mounted on a rolling wire cart and comes with two large M-Series reagent containers (ORI-CLEAN Plus and ORI-GLO Plus, 5 gallons each), a Reagent 3 container, an ORIGEN Technology Instrumentation Training Material binder, an M-Series M8 Analyzer Operation Manual (Software Version 1.9), and an M-Series M8/384 Analyzers Operation Manual (Software Version 1.9). The rear I/O panel, reagent port fittings, keyboard, floppy drive, and cooling fan are all visible in the photos. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Origen / IGEN International
Model:
M-Series M8
MPN:
M8-1003-0950
Type:
Electrochemiluminescence Toxin Analyzer
SKU:
42540
Condition:
As-Is / For Parts or Not Working
Seller Notes:
Includes reagent containers, ORIGEN Training Material binder, and two M-Series M8 Operation Manuals
Power Requirements:
100-120 / 200-230V AC, 50-60Hz
Current Rating:
10A (100-120V) / 5A (200-230V)
Revision:
D
Application / Use Case:
Food, water, and environmental borne toxin detection
Technology:
Electrochemiluminescence (ECL)
Form Factor:
Benchtop / Cart-mounted
Display:
Color LCD touchscreen
Keyboard:
Integrated compact QWERTY keyboard
Floppy Drive:
3.5-inch floppy disk drive (built-in)
Reagent Ports:
Reagent 1, Reagent 2, Reagent 3, Waste (level-detect)
Connectivity:
COM A, COM B (DB9), Video, Printer Port (DB25), Network (RJ45), Modem (RJ11)
Laser Classification:
Class 1 Laser Product; IEC 60825-1: 1993+A1+A2 (Class 2 when open)
Manufacturer Location:
IGEN International, Inc., Gaithersburg, MD 20877
Country/Region of Manufacture:
United States
Compatible Reagents:
Origen ORI-CLEAN Plus, ORI-GLO Plus (M-Series)
Compatible Models:
M-Series M8, M-Series M8/384
Software Version:
1.9 (per included operation manuals)