Narda

Narda Microline 66A3A Peak Power Meter Milliwatts Bolometer RF Test

(No reviews yet) Write a Review
SKU:
18532
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
15.00 LBS
Shipping:
Calculated at Checkout
  • Narda Microline 66A3A Peak Power Meter — front panel with analog milliwatt display, power/mode rotary switch, input BNC, and CAL ADJ knob; Sierra Research Corporation No. 1372 badge visible
  • Narda Microline 66A3A Peak Power Meter — rear panel showing Bolometer Selector, Bias Adj BNC connectors (P3881, P3887, P605, P3083), Meter Zero knob, Recorder output, and AC power cord; serial number D2016 visible
  • Narda Microline 66A3A Peak Power Meter — close-up of front panel showing analog Milliwatts Peak Power scale (0–30 / 0–10 sub-scale), BOLO TEST/OPER/CAL switch, VIDEO OUT BNC, range switch (10–30–100–300 mW), and Sierra Research No. 1903 badge
$45.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Narda Microline 66A3A Peak Power Meter Milliwatts Bolometer RF Test

The Narda Microline 66A3A is a benchtop analog peak power meter designed to measure pulsed and CW RF power in milliwatts. It uses interchangeable bolometer elements to sense power at the measurement point, displaying the result on a large analog meter scale calibrated in Milliwatts Peak Power. The instrument was produced by Narda Microline, a well-regarded name in microwave and RF instrumentation.

Specifications & What's Included

  • Model: Narda Microline 66A3A Peak Power Meter
  • Display: Analog panel meter — Milliwatts Peak Power (dual scale: 0–30 and 0–10 mW visible)
  • Range Switch: 10, 30, 100, 300 milliwatts
  • Power Source: AC line or internal battery (AC / BAT / CHG selectable via front rotary switch)
  • Front Panel Controls: Power/mode switch (OFF / AC / BAT / CHG), function switch (BOLO TEST / OPER / CAL), range/milliwatts selector, CAL ADJ knob
  • Front Panel Connectors: INPUT (BNC), VIDEO OUT (BNC)
  • Rear Panel: Bolometer Selector (P3881, P3887, P605, P3083), Bias Adj BNC connectors, Meter Zero control, Recorder output (BNC), AC power cord
  • Form Factor: Benchtop, self-contained metal enclosure
  • Included: Meter unit only — no bolometer elements, probes, or cables included

Applications

Peak power meters of this type were standard instruments in microwave and RF laboratories from the 1960s through the 1980s, used to measure the peak power of pulsed radar signals, microwave transmitters, and other RF sources where average-power measurements would be misleading. The bolometer-based sensing method — where a thin resistive element absorbs RF energy and changes resistance as it heats — was a well-established technique for low-level microwave power measurement. The 66A3A's multiple bolometer positions on the rear-panel selector allowed the instrument to be calibrated for different Narda bolometer elements (such as the P3881, P3887, P605, and P3083 series), each suited to a specific frequency range or power level. Instruments like this were commonly found in defense electronics labs, university microwave research facilities, and industrial RF testing environments. They remain useful today for anyone maintaining or characterizing vintage microwave equipment, radar systems, or for educational purposes in RF/microwave courses where bolometer-based power measurement is taught.

Condition: Used
This Narda Microline 66A3A Peak Power Meter came from a retired electrical engineer's collection. It has not been fully tested at our facility. The unit shows the kind of wear you'd expect from a piece of vintage RF test equipment — light surface scuffing on the metal enclosure and some discoloration on the front panel label, consistent with age and use in a lab environment. The analog meter face, rotary switches, and knobs all appear intact and undamaged. The rear panel Bolometer Selector, Bias Adj connectors, Meter Zero control, and Recorder output are all present. No bolometer elements, probes, or cables are included. Please review all photos carefully and contact us with any questions before purchasing.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Narda
Model:
66A3A
MPN:
66A3A
Type:
Peak Power Meter
SKU:
18532
Display Type:
Analog Meter (Milliwatts Peak Power)
Measurement Type:
Peak RF Power (Milliwatts)
Power Source:
AC / Battery (BAT/CHG selectable)
Input Connector:
BNC (front panel INPUT)
Output:
VIDEO OUT — BNC; RECORDER — rear panel
Bolometer Selector:
P3881, P3887, P605, P3083 (rear panel)
Controls:
OFF/AC/BAT/CHG, BOLO TEST, OPER, CAL, Milliwatts range, CAL ADJ
Range Switch:
10, 30, 100, 300 Milliwatts
Bias Adjustment:
Rear panel BIAS ADJ with multiple BNC connectors
Meter Zero:
Rear panel METER ZERO control
Form Factor:
Benchtop
Seller Notes:
Unit only — no bolometer elements, probes, or cables included.
Country/Region of Manufacture:
United States
Condition Notes:
This Narda Microline 66A3A Peak Power Meter came from a retired electrical engineer and has not been fully tested at our facility. Shows light cosmetic wear consistent with age. No probes or cables included. Contact us with questions before buying.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov