Mattson-Garvin

Mattson-Garvin Model 220 Air Sampler 120V 60Hz 28.3 L/min Programmable Timer

(No reviews yet) Write a Review
SKU:
42442
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
18.00 LBS
Shipping:
Calculated at Checkout
  • Mattson-Garvin Model 220 Air Sampler front view — mint green housing with glass dome, rotating arm, digital programmable timer display, and Dwyer flow meter on right side
  • Mattson-Garvin Model 220 Air Sampler rear view — power cord coiled on rear panel, On/Off toggle switch on left side, glass dome and rotating arm assembly visible above
  • Mattson-Garvin Model 220 nameplate label — Model 220, Serial No. 2808, Supply 120V, Freq 60
  • Mattson-Garvin Model 220 front panel close-up — red LED programmable timer display showing 10:00, Time Select up/down buttons, Start/Stop button, and Dwyer SCFH air rotameter
  • Mattson-Garvin Model 220 Dwyer SCFH air rotameter and On indicator light close-up — red lighted indicator and toggle switch in Off position
  • Mattson-Garvin Model 220 rotating slit sampler arm assembly — mint green synchronous motor drum with cross-arm and white circular gasket ring on top of instrument housing
  • Mattson-Garvin Model 220 underside — Pall Ultipor N66 0.2 micron disposable filter assembly (DFA4001NAEY) attached to vacuum pump outlet with gray power cable bundle visible
$135.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Mattson-Garvin Model 220 Air Sampler 120V 60Hz 28.3 L/min Programmable Timer

The Mattson-Garvin Model 220 is a benchtop slit air sampler designed for environmental particle monitoring in cleanrooms, laboratories, and controlled environments. It draws ambient air through a precision 0.152 mm slit at a fixed flow rate of 28.3 litres per minute, depositing airborne particles — including viable microorganisms — onto a collection surface mounted on the rotating drum assembly beneath the glass dome. A built-in vacuum pump drives airflow, and the synchronous 1 RPH drive motor turns the collection surface at a consistent, calibrated rate for time-resolved sampling.

Specifications & What's Included

  • Manufacturer: Mattson-Garvin (distributed by Barramundi Corp.)
  • Model: 220
  • Supply Voltage: 120V AC
  • Frequency: 60 Hz
  • Airflow Rate: 28.3 litres/minute
  • Slit Width: 0.152 mm
  • Drive Motor: 1 RPH synchronous motor
  • Timer: Digital LED display programmable timer with Time Select (up/down) and Start/Stop buttons
  • Power Switch: On/Off toggle switch with lighted red On indicator
  • Flow Meter: Dwyer SCFH air rotameter (right side panel)
  • Pump: Built-in vacuum pump
  • Filter: Pall Ultipor N66 0.2 micron absolute disposable filter assembly, P/N DFA4001NAEY
  • Glass dome collection chamber with rotating slit arm assembly and white sealing gasket ring
  • Form Factor: Benchtop
  • Housing Color: Mint green painted steel

Applications

The Mattson-Garvin Model 220 is used for environmental microbial and particle monitoring in cleanrooms, pharmaceutical manufacturing areas, hospital operating rooms, food processing facilities, and research laboratories. Slit samplers like the Model 220 are a standard method for collecting time-resolved air samples onto agar contact plates or other collection media — the rotating drum advances the collection surface beneath the slit at a known rate, allowing the operator to correlate particle deposition with specific time intervals during the sampling run. The programmable timer and fixed 28.3 L/min flow rate make it straightforward to standardize sampling protocols across multiple monitoring points. This type of instrument is commonly used alongside particle counters to give both viable (biological) and total particle counts for cleanroom qualification, environmental monitoring programs (EMPs), and regulatory compliance in FDA-regulated or ISO-classified spaces.

Condition: Used
This Mattson-Garvin Model 220 Air Sampler has been pulled from a working environment where it was previously in service. The unit has been visually inspected and photographed. The mint green housing shows light surface wear consistent with normal laboratory use. The glass dome, rotating slit arm, and Dwyer flow meter appear intact and undamaged. The front-panel digital timer display, Start/Stop controls, and lighted On indicator are present. A Pall Ultipor N66 0.2 micron disposable filter assembly (DFA4001NAEY) is attached. The unit has not been powered up or tested at our facility. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Mattson-Garvin
Model:
220
MPN:
220
Type:
Air Sampler / Slit Sampler
SKU:
42442
Voltage:
120V
Frequency:
60 Hz
Flow Rate:
28.3 litres/minute
Slit Width:
0.152 mm
Drive Motor:
1 RPH synchronous motor
Timer:
Digital display programmable timer
Pump:
Built-in vacuum pump
Flow Meter:
Dwyer SCFH air rotameter
Filter:
Pall Ultipor N66 0.2 micron disposable filter assembly
Filter Part Number:
DFA4001NAEY
Controls:
On/Off toggle switch, lighted On indicator, Start/Stop
Form Factor:
Benchtop
Application:
Cleanroom air quality / particle sampling
Country/Region of Manufacture:
United States
Seller Notes:
Includes glass dome, rotating arm assembly, Pall Ultipor N66 filter, and power cord.
Condition Notes:
This Mattson-Garvin Model 220 Air Sampler was pulled from a working environment. Housing shows light wear. Glass dome, rotating arm, flow meter, and filter assembly present. Not powered or tested at our facility. Please contact us with any questions.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov