Link Systems

Link Systems ETEC A/S Cryogenic Si(Li) Detector LN2 Dewar 10mm2 -400V Bias

(No reviews yet) Write a Review
SKU:
31332
MPN:
ETEC A/S
Condition:
Used
Availability:
Usually ships within 1-2 business days.
Weight:
15.00 LBS
Shipping:
Calculated at Checkout
  • Link Systems ETEC A/S cryogenic detector with light blue LN2 Dewar and mounting assembly – front view showing 'LIQUID NITROGEN' label
  • Link Systems ETEC A/S cryogenic LN2 Dewar detector assembly – side view showing data plate and linear slide mount
  • Close-up of detector snout and linear positioning rod on Microtrace scale showing approximately 10cm length
  • Link Systems Ltd OPT Pre Amp 1166 preamplifier box showing H.V., P.A. Power, and Output connectors including DB-9 port
  • Link Systems logo decal on LN2 Dewar body – copper/orange trademark logo on light blue casing
  • Data plate on Link Systems ETEC A/S detector: Model ETEC A/S, Det. Area 10mm2, Det. Bias -400V, Window 0.008 MM, Resolution at 5.9 keV
  • Close-up of detector snout tip showing circular detector window and surrounding metalwork with wiring visible
  • Detailed view of detector snout body showing wiring harness (blue, orange, other leads) soldered to internal components
  • Ruler measurement showing detector snout window diameter at approximately 12–13mm scale reference
  • Underside view of detector snout assembly showing wiring harness with blue zip ties and solder connections on aluminum body
  • Link Systems Cryogenic Detector with a Dewar for LN2 ETEC A/S - AS IS
$350.00
Was: $700.00
Current Stock: 1

Sold Out

Description

Link Systems ETEC A/S Cryogenic Si(Li) Detector LN2 Dewar 10mm² -400V Bias

Cryogenic silicon-lithium X-ray detector system designed for energy-dispersive spectroscopy (EDS) and elemental analysis. Operates with liquid nitrogen cooling and includes a preamplifier for signal conditioning.

Specifications & What's Included

  • Detector area: 10mm²
  • Operating bias: -400V
  • Window thickness: 0.008mm
  • LN2 Dewar (approximately 17.5in height, 8.5in diameter)
  • OPT Pre Amp 1166 preamplifier with DB-9 connectors (H.V., P.A. Power, Output)
  • Manufactured in United Kingdom

Applications

Si(Li) detectors are used in scanning electron microscopy (SEM), electron microprobe analysis, and X-ray fluorescence for elemental composition determination. This configuration supports EDS systems requiring cryogenic cooling and preamplified output signals.

Condition: For Parts or Not Working
This Link Systems ETEC A/S Cryogenic Si(Li) X-Ray Detector is being sold AS-IS for parts or repair. The unit has been visually inspected. Functionality has not been verified — the detector is not guaranteed operational and is sold without any functional warranty. The LN2 Dewar appears intact with no visible cracks or damage to the outer casing. The OPT Pre Amp 1166 preamplifier box and mounting/positioning assembly are included. The detector snout shows typical wear consistent with lab use; wiring inside the snout body is visible and intact in the photos. Buyers should evaluate all photos carefully and contact us with any technical questions prior to purchase. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Link Systems Ltd
Model:
ETEC A/S
MPN:
ETEC A/S
Type:
Cryogenic Si(Li) X-Ray Detector with LN2 Dewar
SKU:
31332
Condition:
As-Is / For Parts or Not Working
Seller Notes:
Includes LN2 Dewar (approx. 17.5in tall, 8.5in dia.) and OPT Pre Amp 1166 preamplifier box
Detector Area:
10mm²
Detector Bias:
-400V
Window Size:
0.008 MM (as labeled)
Resolution:
At 5.9 keV (value not fully legible on label)
Preamplifier:
OPT Pre Amp 1166
Connectors:
H.V., P.A. Power, Output (DB-9 on preamplifier box)
Cooling Method:
Liquid Nitrogen (LN2)
LN2 Dewar Height (to top):
Approx. 17.5 in.
LN2 Dewar Height (to seam):
Approx. 15 in.
LN2 Dewar Diameter:
Approx. 8.5 in.
Application / Use Case:
EDS / X-ray spectrometry, SEM, electron microprobe
Country/Region of Manufacture:
United Kingdom
Condition Notes:
Link Systems ETEC A/S cryogenic Si(Li) X-ray detector sold AS-IS for parts or repair. Not tested or guaranteed functional. Visually inspected. LN2 Dewar and OPT Pre Amp 1166 included.