Labconco

Labconco 36205 Purifier Class II Type B2 Biological Safety Cabinet 3ft 115V

(No reviews yet) Write a Review
SKU:
19703
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
570.00 LBS
Shipping:
Calculated at Checkout
  • Labconco 36205 Purifier Class II Biological Safety Cabinet – full front view with sash partially raised, fluorescent interior lighting on, on freestanding stand
  • Labconco 36205 Purifier Class II Biological Safety Cabinet – rear view showing exhaust plenum, back panel, and base stand
  • Labconco 36205 interior work zone – sash fully raised, UV/fluorescent lamp illuminated, stainless steel work surface and perforated rear wall visible
  • Labconco 36205 front panel – Dwyer Minihelic differential pressure gauge close-up, needle reading approximately 0.5 in. w.g.
  • Labconco 36205 Technical Safety Services certification label – NSF-49 Annex F certified, model 36205, S/N 600563, tested 08/2004, avg velocity 126 fpm, ΔP 0.52 in. w.g.
  • Labconco 36205 front control panel – Purifier Class II Safety Cabinet nameplate with blower, light, and UV rocker switches and Minihelic gauge
$2,600.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Labconco 36205 Purifier Class II Type B2 Biological Safety Cabinet 3ft 115V

The Labconco 36205 is a 3-foot (36-inch) Class II, Type B2 total-exhaust biological safety cabinet from Labconco's Purifier line. Type B2 cabinets exhaust 100% of cabinet air to the building exhaust system — no recirculation — making them the appropriate choice for work with volatile toxic chemicals and radionuclides in addition to biological agents. The unit provides personnel, product, and environmental protection through HEPA-filtered inflow and downflow air, with all exhaust directed externally via a hard-ducted connection.

Specifications & What's Included

  • Model: Labconco 36205
  • Cabinet class: Class II, Type B2 Total Exhaust Biological Safety Cabinet
  • Nominal width: 3 ft (36 inches)
  • Voltage: 115V AC
  • Frequency: 60 Hz
  • Current draw: 12 Amps
  • Power cord & plug rating: 115V, 15 Amps
  • Exhaust volume: 743–771 CFM
  • Sash opening: 8 inches
  • Lighting: Fluorescent lamp (interior work zone illumination)
  • UV lamp: Present and visible in photos
  • Airflow monitoring: Dwyer Minihelic differential pressure gauge (front-panel mounted)
  • Front controls: Blower on/off, Light on/off, UV on/off rocker switches
  • Supply HEPA filter replacement P/N: 3739400
  • Exhaust HEPA filter replacement P/N: 3739500
  • Certifications: NSF-49 Annex F, ETL, ADA compliant
  • Historical TSS field certification label present (test date 08/2004, avg face velocity 126 fpm, ΔP 0.52 in. w.g.) — new field certification required before regulated use
  • Cabinet only — no accessories included

Applications

Class II Type B2 biological safety cabinets are used in microbiology, cell culture, pharmaceutical research, and any laboratory application requiring simultaneous protection of the operator, the work, and the environment from biological hazards. Because the Labconco Purifier Type B2 design exhausts 100% of its airflow externally, it is particularly well suited for procedures involving low-to-moderate concentrations of volatile toxic chemicals or radionuclides alongside biological agents — applications where a recirculating Type A cabinet would be unsafe. These cabinets are standard equipment in biosafety level 2 (BSL-2) and BSL-3 facilities, clinical and hospital laboratories, pharmaceutical quality control labs, and university life sciences departments. The 3-foot work zone width makes the 36205 a common choice for individual researcher benches where floor space is limited. A new field certification to NSF-49 by a qualified service technician is required before the cabinet is placed back into active regulated service after relocation.

Condition: Used
This Labconco 36205 Purifier Class II Type B2 Biological Safety Cabinet is used surplus equipment pulled from a working laboratory environment. The cabinet has been visually inspected and photographed. The interior work zone and stainless work surface show normal use wear. The fluorescent and UV lamps appear intact, the Minihelic airflow gauge is present, and the blower, light, and UV rocker switches on the front control panel are all present. A Technical Safety Services (TSS) NSF-49 Annex F certification label is affixed to the unit and shows a test date of August 2004 with an average face velocity of 126 fpm and a static pressure of 0.52 in. w.g. — note this certification is historical and a new field certification will be required before the cabinet is placed back into regulated service. It has not been powered or tested at our facility. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Labconco
Model:
36205
MPN:
36205
SKU:
19703
Type:
Class II Type B2 Biological Safety Cabinet
Nominal Width:
3 ft (36 inches)
Cabinet Class:
Class II, Type B2 Total Exhaust
Voltage:
115V AC
Current Draw:
12 Amps
Frequency:
60 Hz
Power Cord & Plug Rating:
115V, 15 Amps
Exhaust Volume:
743–771 CFM
Sash Opening:
8 inches
Lighting:
Fluorescent
UV Light:
Yes (UV lamp included)
Airflow Gauge:
Dwyer Minihelic differential pressure gauge
HEPA Filter – Supply PN:
3739400
HEPA Filter – Exhaust PN:
3739500
Compliance / Certifications:
NSF-49 Annex F, ETL, ADA
Controls:
Blower on/off switch, Light on/off switch, UV on/off switch
Form Factor:
Freestanding Floor Cabinet
Power Requirements:
115V AC, 60Hz, 12A
Country/Region of Manufacture:
United States
Seller Notes:
Cabinet only — no accessories included.
Condition Notes:
This Labconco 36205 Class II Type B2 Biological Safety Cabinet is used, pulled from a working lab. Visually inspected; lamp and gauges appear intact. Not powered or tested at our facility.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov