Labconco 36205 Purifier Class II Type B2 Biological Safety Cabinet 3ft 115V
The Labconco 36205 is a 3-foot (36-inch) Class II, Type B2 total-exhaust biological safety cabinet from Labconco's Purifier line. Type B2 cabinets exhaust 100% of cabinet air to the building exhaust system — no recirculation — making them the appropriate choice for work with volatile toxic chemicals and radionuclides in addition to biological agents. The unit provides personnel, product, and environmental protection through HEPA-filtered inflow and downflow air, with all exhaust directed externally via a hard-ducted connection.
Specifications & What's Included
- Model: Labconco 36205
- Cabinet class: Class II, Type B2 Total Exhaust Biological Safety Cabinet
- Nominal width: 3 ft (36 inches)
- Voltage: 115V AC
- Frequency: 60 Hz
- Current draw: 12 Amps
- Power cord & plug rating: 115V, 15 Amps
- Exhaust volume: 743–771 CFM
- Sash opening: 8 inches
- Lighting: Fluorescent lamp (interior work zone illumination)
- UV lamp: Present and visible in photos
- Airflow monitoring: Dwyer Minihelic differential pressure gauge (front-panel mounted)
- Front controls: Blower on/off, Light on/off, UV on/off rocker switches
- Supply HEPA filter replacement P/N: 3739400
- Exhaust HEPA filter replacement P/N: 3739500
- Certifications: NSF-49 Annex F, ETL, ADA compliant
- Historical TSS field certification label present (test date 08/2004, avg face velocity 126 fpm, ΔP 0.52 in. w.g.) — new field certification required before regulated use
- Cabinet only — no accessories included
Applications
Class II Type B2 biological safety cabinets are used in microbiology, cell culture, pharmaceutical research, and any laboratory application requiring simultaneous protection of the operator, the work, and the environment from biological hazards. Because the Labconco Purifier Type B2 design exhausts 100% of its airflow externally, it is particularly well suited for procedures involving low-to-moderate concentrations of volatile toxic chemicals or radionuclides alongside biological agents — applications where a recirculating Type A cabinet would be unsafe. These cabinets are standard equipment in biosafety level 2 (BSL-2) and BSL-3 facilities, clinical and hospital laboratories, pharmaceutical quality control labs, and university life sciences departments. The 3-foot work zone width makes the 36205 a common choice for individual researcher benches where floor space is limited. A new field certification to NSF-49 by a qualified service technician is required before the cabinet is placed back into active regulated service after relocation.
This Labconco 36205 Purifier Class II Type B2 Biological Safety Cabinet is used surplus equipment pulled from a working laboratory environment. The cabinet has been visually inspected and photographed. The interior work zone and stainless work surface show normal use wear. The fluorescent and UV lamps appear intact, the Minihelic airflow gauge is present, and the blower, light, and UV rocker switches on the front control panel are all present. A Technical Safety Services (TSS) NSF-49 Annex F certification label is affixed to the unit and shows a test date of August 2004 with an average face velocity of 126 fpm and a static pressure of 0.52 in. w.g. — note this certification is historical and a new field certification will be required before the cabinet is placed back into regulated service. It has not been powered or tested at our facility. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
Labconco |
Model: |
36205 |
MPN: |
36205 |
SKU: |
19703 |
Type: |
Class II Type B2 Biological Safety Cabinet |
Nominal Width: |
3 ft (36 inches) |
Cabinet Class: |
Class II, Type B2 Total Exhaust |
Voltage: |
115V AC |
Current Draw: |
12 Amps |
Frequency: |
60 Hz |
Power Cord & Plug Rating: |
115V, 15 Amps |
Exhaust Volume: |
743–771 CFM |
Sash Opening: |
8 inches |
Lighting: |
Fluorescent |
UV Light: |
Yes (UV lamp included) |
Airflow Gauge: |
Dwyer Minihelic differential pressure gauge |
HEPA Filter – Supply PN: |
3739400 |
HEPA Filter – Exhaust PN: |
3739500 |
Compliance / Certifications: |
NSF-49 Annex F, ETL, ADA |
Controls: |
Blower on/off switch, Light on/off switch, UV on/off switch |
Form Factor: |
Freestanding Floor Cabinet |
Power Requirements: |
115V AC, 60Hz, 12A |
Country/Region of Manufacture: |
United States |
Seller Notes: |
Cabinet only — no accessories included. |
Condition Notes: |
This Labconco 36205 Class II Type B2 Biological Safety Cabinet is used, pulled from a working lab. Visually inspected; lamp and gauges appear intact. Not powered or tested at our facility. |