Description
Lab-Tek Tissue-Tek II 4613 Vacuum Infiltrator 115VAC 60Hz Paraffin Lab
The Lab-Tek Tissue-Tek II Model 4613 is a benchtop vacuum infiltrator designed for histology and pathology specimen processing. Its primary function is to infuse liquid paraffin into tissue specimens under vacuum, removing air voids, residual clearing agents, and other gases (de-gassing) to ensure thorough, consistent infiltration before embedding. The unit may also be used for formalin fixation prior to standard tissue processing. This unit is missing its lid and is priced accordingly.
Specifications & What's Included
- Manufacturer: Lab-Tek Division, Miles Laboratories, Inc., Naperville, IL
- Model: 4613
- Product Line: Tissue-Tek II
- Intended Use: For In Vitro Diagnostic Use
- Power: 115VAC, 60Hz, 1 Amp, 100 Watts
- Overall Dimensions: 152 x 178 x 235 mm (6 x 7 x 9-1/4 in)
- Certification: CSA (File No. LR25318)
- Country of Manufacture: USA
- Includes: Aluminum basket with slotted vents (for capsules and/or cassettes)
- Missing: Vacuum lid (not included — priced accordingly)
- Visible interior residue: solidified paraffin in chamber bowl
- Rear: vacuum port fitting present
- Front panel: Tissue-Tek II nameplate with temperature indicator (C/H scale)
Applications
The Tissue-Tek II Vacuum Infiltrator was a standard piece of histology lab equipment used in hospital pathology departments, research institutions, and clinical laboratories during the 1970s and 1980s — the era when the Tissue-Tek line from Miles Laboratories was among the most widely adopted systems in histological specimen preparation. Vacuum infiltration is a critical step in the tissue processing workflow: by holding the specimen in molten paraffin under reduced atmospheric pressure, air and residual processing solvents are drawn out of the tissue matrix, producing well-infiltrated blocks that section cleanly under a microtome. The Model 4613 was also used for formalin fixation, making it a versatile benchtop unit for smaller labs. The aluminum slotted basket accommodates standard histology cassettes and tissue capsules. Replacement lids and compatible accessories for Tissue-Tek II units are sometimes available through histology supply channels and lab surplus markets.
This Lab-Tek Tissue-Tek II Model 4613 Vacuum Infiltrator is in used condition and is missing its lid. The unit has not been powered up or tested at our facility, but it came out of a lab environment where it was previously in service. The exterior shows general wear consistent with lab use, and there is solidified paraffin residue visible inside the chamber bowl. The aluminum slotted basket is present. Because the lid is missing, this unit is priced accordingly and is being sold as-is. Please review our photos carefully and contact us with any questions before purchasing.
Warranty Information
Additional Information
Brand: |
Lab-Tek |
Model: |
4613 |
MPN: |
4613 |
Product Line: |
Tissue-Tek II |
Type: |
Vacuum Infiltrator |
SKU: |
35610 |
Application: |
Histology paraffin infiltration, specimen de-gassing |
Power Requirements: |
115VAC, 60Hz, 1 Amp, 100 Watts |
Voltage: |
115VAC |
Frequency: |
60Hz |
Current Rating: |
1 Amp |
Power Consumption: |
100 Watts |
Dimensions: |
152 x 178 x 235 mm (6 x 7 x 9-1/4 in) |
Certifications: |
CSA (LR25318) |
Country/Region of Manufacture: |
United States |
Manufacturer: |
Miles Laboratories, Inc., Naperville, IL |
Intended Use: |
For In Vitro Diagnostic Use |
Included Accessories: |
Aluminum basket with slotted vents |
Missing Parts: |
Lid missing |
Seller Notes: |
Includes aluminum slotted basket. Lid is missing — priced accordingly. |
Condition Notes: |
Lab-Tek Tissue-Tek II 4613 Vacuum Infiltrator — used, missing lid. Not tested at our facility; pulled from a working lab environment. Solidified paraffin residue in chamber. Aluminum basket included. Sold as-is due to missing lid. |
California Prop 65 Warning: |
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov |