Description
HP 8721A OPT. 008 75 Ohm Directional Bridge RF Reflectometer BNC
The HP 8721A OPT. 008 is a passive 75 ohm directional bridge used to separate incident and reflected RF signals on a transmission line. Option 008 configures the bridge for 75 ohm impedance environments, making it suited for cable television, broadcast, and RF distribution systems that use 75 ohm coaxial infrastructure. The device provides 6 dB coupling on both the incident and reflected ports via BNC connectors.
Specifications & What's Included
- Model: HP 8721A OPT. 008
- Manufacturer: Hewlett-Packard
- Type: Directional Bridge (passive RF reflectometer)
- Impedance: 75 ohm
- Option: OPT. 008 (75 ohm configuration)
- Coupling Factor: 6 dB (incident port); 6 dB (reflected port)
- Labeled ports: SOURCE, LOAD, INCIDENT, REFLECTED
- Connector Type: BNC (all four ports)
- Form Factor: Compact octagonal inline passive device
- Bridge only — no cables, adapters, or accessories included
Applications
Directional bridges like the HP 8721A are used in RF test setups to measure return loss, VSWR (voltage standing wave ratio), and reflection coefficients on 75 ohm transmission lines and components. The 8721A is designed to work with scalar network analyzers and power meters — the SOURCE port connects to the RF signal source, the LOAD port connects to the device under test, and the INCIDENT and REFLECTED ports feed detectors or meters to compare forward and reflected power. This 75 ohm variant (OPT. 008) was commonly used in CATV system testing, broadcast RF plant maintenance, and laboratory characterization of 75 ohm components such as splitters, amplifiers, and cable runs. Hewlett-Packard produced the 8721-series directional bridges as accessories for its scalar measurement systems, particularly the 8757-series scalar network analyzers, during the 1980s and into the 1990s.
This HP 8721A OPT. 008 75 Ohm Directional Bridge has been inspected and appears to be in good used condition. It shows normal wear consistent with previous lab or field use — the body and face panels are intact with no cracks or breaks visible, and all four BNC ports appear clean and undamaged. This unit has not been powered up or tested at our facility, but it was pulled from a working environment where it was previously in use. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
HP |
Model: |
8721A |
MPN: |
8721A OPT. 008 |
Type: |
Directional Bridge / RF Reflectometer |
SKU: |
33291 |
Impedance: |
75 Ohm |
Coupling Factor: |
6 dB |
Connector Type: |
BNC |
Ports: |
Source, Load, Incident, Reflected |
Option: |
OPT. 008 |
Seller Notes: |
Bridge only — no cables or accessories |
Country/Region of Manufacture: |
United States |
Form Factor: |
Handheld / Inline Passive Device |
Condition Notes: |
This HP 8721A OPT. 008 75 Ohm Directional Bridge has been inspected and is in good used condition with normal wear. All BNC ports appear clean and undamaged. Not tested at our facility; pulled from a working environment. |