HP

HP 5342A Microwave Frequency Counter 10Hz-18GHz HP-IB For Parts No Display

(No reviews yet) Write a Review
SKU:
24791
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
22.00 LBS
Shipping:
Calculated at Checkout
  • HP 5342A Microwave Frequency Counter – front and right-side view showing front panel, keypad, LED display digits, and carry handle
  • HP 5342A Microwave Frequency Counter – rear-left view showing ventilation panel, rear BNC connectors, and carry handle
  • HP 5342A Microwave Frequency Counter – close-up front panel showing LED display array labeled GHz/MHz/KHz/Hz, numeric keypad, frequency/attenuation selector switches, and BNC input connectors
  • HP 5342A Microwave Frequency Counter – rear panel close-up showing HP-IB connector, serial number label, IEC power inlet, CW/FM inputs, Freq Std In/Out, IF Out, DAC, and 10 MHz reference connectors
$650.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

HP 5342A Microwave Frequency Counter 10Hz-18GHz HP-IB For Parts No Display

The HP 5342A is a benchtop microwave frequency counter covering 10 Hz to 18 GHz across two selectable input ranges, with an 11-digit LED readout and HP-IB (GPIB) interface for automated test system integration. This unit powers on but the display is non-functional and produces no readout. It is being sold strictly AS-IS for parts or repair — it is not guaranteed operational.

Specifications & What's Included

  • Make / Model: Hewlett-Packard HP 5342A
  • Option: 011
  • Type: Microwave Frequency Counter
  • Frequency range: 10 Hz to 18 GHz (split into 2 ranges)
  • Display: 11-digit LED array (GHz / MHz / KHz / Hz segments) — non-functional on this unit
  • Input impedance: 50 Ohms or 1 MOhm (selectable via front-panel switch)
  • FM signal tolerance: up to 50 MHz peak-to-peak
  • Front-panel inputs: 50 Ohm BNC (10 GHz / 18 GHz range), 1 MOhm BNC (500 MHz range)
  • Interface: HP-IB (GPIB) — rear-panel connector visible
  • Rear-panel connectors: CW/FM signal inputs, Freq Std In, Freq Std Out, IF Out, DAC output, 10 MHz In/Out reference
  • Form factor: benchtop portable with integrated carry handle
  • Powers on — display does not function; sold AS-IS

Applications

The HP 5342A was introduced in the late 1970s as part of Hewlett-Packard's line of microwave frequency counters, designed for precise frequency measurement from audio through microwave frequencies up to 18 GHz. It was widely used in RF and microwave labs, communications test environments, and automated test systems via HP-IB, which later became the IEEE-488 / GPIB standard. The 5342A covered both the low-frequency range (accessed through the high-impedance BNC input) and the microwave range (through the 50-ohm N-type or BNC input), making it a versatile single-instrument solution. These counters remain sought after by vintage HP instrument collectors and by technicians maintaining legacy RF test benches. A non-working or display-faulted unit like this one is a common source of parts — particularly the display board, power supply, and RF input assemblies — for repairing other 5342A instruments with failed main electronics.

Condition: For Parts or Not Working
This HP 5342A Microwave Frequency Counter is being sold AS-IS for parts or repair. The unit powers on but the 11-digit LED display is non-functional — it produces no readout. All other aspects of the instrument's condition have not been verified. This counter is well-suited as a donor unit: the display assembly is a straightforward swap and can typically be removed in about five minutes, making it a practical source of working electronics for a unit with a dead main board. Please review all photos carefully and contact us with any questions before purchasing.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
HP
Model:
5342A
MPN:
5342A
Type:
Microwave Frequency Counter
SKU:
24791
Seller Notes:
Unit only — no manual or accessories confirmed included.
Frequency Range:
10 Hz to 18 GHz
Number of Ranges:
2 (split ranges)
Display:
11-Digit LED (non-functional — sold for parts)
Input Impedance:
50 Ohms or 1 MOhm (selectable)
FM Signal Tolerance:
Up to 50 MHz peak-to-peak
Interface:
HP-IB (GPIB)
Rear Connectors:
CW/FM input, Freq Std In/Out, IF Out, DAC, 10 MHz In/Out
Front Panel Inputs:
50 Ohm BNC (10 GHz–18 GHz), 1 MOhm BNC (500 MHz)
Options:
Option 011
Form Factor:
Benchtop / Portable (with carry handle)
Country/Region of Manufacture:
United States
Condition Notes:
HP 5342A Microwave Frequency Counter — sold AS-IS for parts/repair. Powers on but 11-digit LED display is non-functional (no readout). Not guaranteed operational. Good donor unit — display removal ~5 min.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov