HP

HP 3420B DC Differential Voltmeter Ratiometer Hewlett-Packard 6-Digit Benchtop

(No reviews yet) Write a Review
SKU:
25026
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
25.00 LBS
Shipping:
Calculated at Checkout
  • HP 3420B DC Differential Voltmeter Ratiometer — three-quarter front-left view showing gray benchtop chassis, six thumbwheel decade dials, analog null meter, and rack handles
  • HP 3420B DC Differential Voltmeter Ratiometer — straight-on front panel view showing HP logo, six decade dials, function selector buttons, multiplier knobs, analog null meter, and input binding posts
  • HP 3420B front panel close-up — Hewlett-Packard label, Function buttons (ON/OFF, Fast Chg., Bat. Test, Zero, DC VM, DC ΔVM, Ratio), and x1/x10/x100 multiplier selector knobs
  • HP 3420B rear panel — IEC AC power inlet, voltage selector switch, Amplitude and Recorder output binding posts, fuse holder, and yellow caution sticker
  • HP 3420B rear panel mid-angle — Amplitude and Recorder (+ and −) binding posts, IEC inlet, 95/230V selector, and red CAUTION label visible
  • HP 3420B rear panel close-up — power rating label (95/230V, 48–440Hz), 62 mA fuse rating, voltage selection switch, IEC AC inlet, and Recorder output binding posts
$600.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

HP 3420B DC Differential Voltmeter Ratiometer Hewlett-Packard 6-Digit Benchtop

The HP 3420B is a precision DC Differential Voltmeter and Ratiometer made by Hewlett-Packard. It uses a null-balance measurement technique to compare an unknown DC voltage against an internal precision reference, achieving high accuracy without loading the circuit under test. The six-digit thumbwheel decade-dial readout sets the reference voltage directly, and the front-panel analog galvanometer indicates null balance. The instrument also operates as a ratiometer, making it useful for comparing two voltages as a ratio — a capability valued in calibration and standards work.

Specifications & What's Included

  • Manufacturer: Hewlett-Packard (HP)
  • Model: 3420B DC Differential Voltmeter/Ratiometer
  • Display: 6-digit thumbwheel decade dials (manual balance)
  • Null indicator: Analog galvanometer meter (front panel)
  • Measurement modes: DC VM, DC ΔVM (differential/delta voltage), Ratio (A÷B)
  • Range multipliers: ×1, ×10, ×100 (front-panel rotary selectors)
  • Function buttons: ON/OFF, Fast Charge, Battery Test, Zero, DC VM, DC ΔVM, Ratio
  • Internal battery with Fast Charge and Battery Test functions (battery-operable)
  • Power: 95/230V AC, 48–440Hz (wide-range), ~7.8VA
  • Fuse: 62 mA
  • Voltage selection: 95V / 230V rear-panel switch
  • AC inlet: IEC connector (rear panel)
  • Rear outputs: Amplitude output (binding posts); Recorder output (+ and − binding posts)
  • Form factor: Benchtop chassis with side rack handles
  • What's included: HP 3420B instrument only — no cables or accessories observed

Applications

The HP 3420B belongs to Hewlett-Packard's classic line of precision DC measurement instruments developed in the 1960s and 1970s for calibration laboratories, standards work, and precision analog circuit development. Differential voltmeters like the 3420B are used wherever a highly accurate, high-input-impedance DC voltage measurement is needed without disturbing the source — particularly in comparing a working voltage standard against a reference, verifying the output of precision voltage sources, and measuring small differential voltages superimposed on larger DC levels. The ratiometer function extends its use to tasks such as comparing two voltage references directly as a ratio, which is valuable in divider calibration and transducer characterization. This class of instrument was a fixture in government, military, and industrial calibration labs during its era, and examples in working condition are still sought by metrology enthusiasts, vintage test equipment collectors, and labs that maintain legacy calibration chains.

Condition: Used
This HP 3420B DC Differential Voltmeter/Ratiometer came to us from a retiring electrical engineer's calibration and product development lab, where it was actively used. It has not been powered up or tested at our facility, but its provenance from a professional working calibration environment is a meaningful indicator of its history. The unit shows cosmetic wear consistent with lab use — the gray chassis has surface scuffs and some discoloration, particularly on the front panel and handles, but the thumbwheel decade dials, function buttons, and front-panel binding posts appear intact. The rear panel shows the AC inlet, voltage selector, fuse holder, and Recorder/Amplitude outputs all in place. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
HP
Model:
3420B
MPN:
3420B
Type:
DC Differential Voltmeter / Ratiometer
SKU:
25026
Display:
6-Digit Thumbwheel Decade Dials
Measurement Modes:
DC VM, DC ΔVM (Delta VM), Ratio
Null Indicator:
Analog galvanometer meter
Power Requirements:
95/230V AC, 48–440Hz, ~7.8VA
Fuse Rating:
62 mA
Voltage Selection:
95V / 230V (rear-panel switch)
Outputs:
Amplitude output; Recorder output (+ and −)
Battery:
Internal battery with Fast Charge and Battery Test functions
Form Factor:
Benchtop with rack handles
Seller Notes:
Unit only — no cables or accessories visible
Country/Region of Manufacture:
United States
Application:
Precision DC voltage comparison, calibration, ratio measurement
Condition Notes:
This HP 3420B DC Differential Voltmeter/Ratiometer came from a retiring engineer's active calibration lab. Shows cosmetic wear typical of professional lab use; all controls and connectors appear intact.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov