Description
HP Hewlett-Packard 3400A RMS AC Voltmeter 1mV-300V 10Hz-10MHz Benchtop
The Hewlett-Packard 3400A is a true RMS AC voltmeter covering a wide voltage range of 1 mV to 300 V across 12 selectable full-scale ranges, with frequency response extending from 10 Hz to 10 MHz. It measures AC voltages using a thermally-based true RMS detection circuit, making it accurate for non-sinusoidal and complex waveforms — not just pure sine waves. The front panel features an analog meter movement with both VOLTS and dB scales, a rotary RANGE selector, and a BNC input connector.
Specifications & What's Included
- Manufacturer: Hewlett-Packard (HP)
- Model: 3400A RMS Voltmeter
- Voltage Range: 1 mV to 300 V full scale, 12 ranges
- Frequency Range: 10 Hz to 10 MHz
- Accuracy (% of full scale): ±5% at 10–50 Hz; ±1% at 1 MHz; ±2% at 2 MHz; ±3% at 3 MHz; ±5% at 10 MHz
- Crest Factor: 10:1 at full scale
- Input Impedance: 10 MΩ / 30 pF (1 mV–300 mV ranges); 10 MΩ / 8 pF (1 V–300 V ranges)
- D.C. Output: Rear-panel BNC connector — outputs a DC voltage proportional to measured AC level
- Power: 115/230 V ±10%, 48–440 Hz, 20 VA max (switchable via rear LINE SELECTOR)
- Fuse: 115/230 V, 250 mA
- AC inlet: IEC connector (rear panel)
- Front panel: Analog meter (VOLTS and dB scales), RANGE rotary selector, INPUT BNC, LINE ON indicator lamp
- Form Factor: Benchtop / portable, with fold-down tilt stand and carry handle
- Unit only — no accessories or cables included
Applications
The HP 3400A was introduced in the late 1960s and became a widely used laboratory and service bench instrument through the 1970s and into the 1980s. Its wide frequency range — stretching from audio frequencies all the way to 10 MHz — makes it useful well beyond standard power-line AC measurements. Typical applications include audio circuit analysis and distortion testing, RF and IF stage voltage measurements in communications equipment, frequency response sweeps on amplifiers and filters, and general AC signal level verification across a broad spectrum. The true RMS response (as opposed to average-responding meters calibrated for RMS) gives it an accuracy advantage when measuring non-sinusoidal waveforms such as square waves, pulse trains, or distorted audio signals. The rear-panel D.C. output allows the voltmeter to drive a chart recorder or data acquisition system for automated or logged measurements. Instruments of this type remain useful in legacy equipment service, vintage radio and audio restoration, and any bench application requiring a reliable wide-band AC voltage reference.
This Hewlett-Packard HP 3400A RMS AC Voltmeter has been inspected and appears to be in good used condition. The case and panel show normal wear consistent with lab use — some light scuffing on the metal housing and handle — but the analog meter, range knobs, and all controls look intact and undamaged. The rear panel labels, accuracy specs, and rating plate are fully legible. It was pulled from a working environment where it was previously in use. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
HP |
Model: |
3400A |
MPN: |
3400A |
Type: |
RMS AC Voltmeter |
SKU: |
39574 |
Voltage Range: |
1 mV to 300 V full scale |
Number of Ranges: |
12 |
Frequency Range: |
10 Hz to 10 MHz |
Power Requirements: |
115/230 V ±10%, 48–440 Hz, 20 VA max |
Fuse: |
115/230V, 250 mA |
Accuracy: |
±5% (10Hz–50Hz); ±1% (1MHz); ±2% (2MHz); ±3% (3MHz); ±5% (10MHz) |
Crest Factor: |
10:1 at full scale |
Input Impedance: |
10 MΩ/30pF (1mV–300mV); 10 MΩ/8pF (1V–300V) |
D.C. Output: |
Yes — rear panel BNC connector |
Form Factor: |
Benchtop / Portable |
Connector Type: |
BNC input, IEC AC inlet, BNC D.C. output |
Seller Notes: |
Unit only — no accessories or cables included. |
Country/Region of Manufacture: |
United States |
Condition Notes: |
This HP 3400A RMS AC Voltmeter has been inspected and is in good used condition with normal lab wear. Pulled from a working environment. Please view our photos and contact us with questions. |
California Prop 65 Warning: |
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov |