null
Hitachi

Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer 139-0171 For Parts

(No reviews yet) Write a Review
SKU:
42066
MPN:
Coleman 139
Condition:
Used
Availability:
Usually ships within 1-2 business days.
Weight:
53.00 LBS
Shipping:
Calculated at Checkout
  • Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer — front-left three-quarter view showing analog meter display and control panel
  • Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer — rear-left three-quarter view showing rear panel connectors and attached cable
  • Hitachi Perkin-Elmer Coleman 139 front panel nameplate closeup reading 'Hitachi Perkin-Elmer UV-VIS Spectrophotometer Coleman 139'
  • Coleman 139 Spectrophotometer analog meter face showing Absorbance and Transmittance dual scales
  • Coleman 139 Spectrophotometer front control panel showing Zero Adj. knob, Selector knob, Slit mm dial, and wavelength dial
  • Coleman 139 Spectrophotometer Slit mm manual adjustment knob closeup
  • Coleman 139 Spectrophotometer wavelength dial closeup showing nm scale with 800 and fine increment markings
  • Hitachi Coleman 139 Spectrophotometer underside/rear showing handwritten annotation '3.5 kV/lux' and multi-pin DIN connector
  • Coleman 139 Spectrophotometer side panel showing Lambda (wavelength) and Slit control entry ports with label plate
  • Coleman 139 Spectrophotometer rear panel Readout section showing multi-pin connector, Output Adjust for Recorder (Fine/Coarse), and Digital output jacks
  • Hitachi Coleman 139 Cell Compartment identification plate — Part No. 139-0171, Serial No. partially visible, Hitachi Ltd. Tokyo Japan, 139-4530
  • Coleman 139 Spectrophotometer cell compartment door area showing W/H selector label and white fiber optic or light guide tube
  • Hitachi Coleman 139 Light Source Compartment identification plate — Part No. 139-01xx (partially obscured), Hitachi Ltd. Japan
  • Coleman 139 Spectrophotometer light source compartment open showing two lamps (tungsten and deuterium-type) and mirror/filter assembly
  • Coleman 139 Spectrophotometer light source compartment alternate angle showing second lamp, mirror mount, and internal optical components
  • Hitachi Coleman 139 Spectrophotometer detached power/signal cable with 3-pin DIN-style male connector
  • Loose internal subassembly from Coleman 139 — small circuit board with DIP switch block, wiring harness, and DB9-style connector laid on workbench
  • Loose connector subassembly from Coleman 139 — DB9-style connector with multi-color ribbon wiring harness
  • Loose subassembly from Coleman 139 — red DIP switch block (positions 1, C1, 2, C2, 3, C3, 4 labeled) on metal bracket with wiring
$500.00
Was: $1,000.00
Current Stock: 1

Sold Out

Description

Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer 139-0171 For Parts

Benchtop UV-VIS spectrophotometer designed for absorbance and transmittance measurements across ultraviolet and visible wavelength ranges. Features dual lamp light source (tungsten and deuterium), manual wavelength and slit width controls, and analog meter display with recorder and digital outputs.

Specifications & What's Included

  • Model: Coleman 139 (MPN 139-0171)
  • Measurement: Absorbance and Transmittance
  • Spectral Range: UV and Visible (UV-VIS)
  • Light Source: Dual lamp (tungsten and deuterium)
  • Display: Analog meter with absorbance and transmittance scales
  • Controls: Manual wavelength dial (nm) and slit width adjustment (mm)
  • Output: Recorder output with fine/coarse adjustment and digital output
  • Connector: Multi-pin DIN-style power/signal cable
  • Includes loose internal subassembly with wiring harness and DIP switch board

Applications

The Coleman 139 spectrophotometer was used in laboratory and analytical settings for quantitative chemical analysis, including pharmaceutical testing, clinical diagnostics, and material analysis. Capable of measuring light absorption across UV and visible wavelengths for concentration determination and spectral characterization. Typically interfaced with recording and data acquisition systems via its recorder and digital outputs.

Condition: For Parts or Not Working
This Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer (P/N 139-0171) is being sold AS-IS for parts or repair. We are not able to confirm functionality due to the unit's age, and no operational testing has been performed. The instrument is cosmetically fair to good for its age — the white housing shows general aging, surface scuffs, and some discoloration, but the analog meter face, front panel controls, and knobs appear intact. The light source compartment is accessible and both lamps are present. A loose internal subassembly (small circuit board with DIP switch block and wiring harness) is included and visible in the photos, though its relationship to the instrument is unclear. The detached multi-pin cable is also included. Please review all photos carefully before purchasing. This unit is not guaranteed functional and is sold strictly as-is. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Hitachi
Model:
Coleman 139
MPN:
139-0171
Secondary Model:
139-4530
SKU:
42066
Type:
UV-VIS Spectrophotometer
Co-Brand:
Perkin-Elmer / Coleman
Measurement Type:
Absorbance and Transmittance
Spectral Range:
UV and Visible (UV-VIS)
Display Type:
Analog meter — Absorbance and Transmittance scales
Light Source:
Dual lamp (tungsten and deuterium visible in photos)
Slit Control:
Manual slit width adjustment knob (mm)
Wavelength Control:
Manual wavelength dial (nm)
Output:
Recorder output (Fine/Coarse adjust), Digital output
Cell Compartment Part No.:
139-0171
Connector:
Multi-pin DIN-style connector (power/signal cable)
Form Factor:
Benchtop
Country/Region of Manufacture:
Japan
Condition:
As-Is / For Parts or Not Working
Seller Notes:
Sold AS-IS for parts or repair. Includes loose internal subassembly with wiring harness and DIP switch board visible in photos.
Condition Notes:
Hitachi Perkin-Elmer Coleman 139 UV-VIS Spectrophotometer (139-0171) sold AS-IS for parts or repair. Not tested or confirmed functional due to age. Cosmetically fair; controls and meter face intact. Loose subassembly and cable included.
View AllClose