Hewlett Packard

HP Hewlett Packard 9100-4117 5KVA Doubly Shielded Isolation Transformer 120V

(No reviews yet) Write a Review
SKU:
32337
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
140.00 LBS
Shipping:
Calculated at Checkout
  • Hewlett Packard 9100-4117 5KVA doubly shielded isolation transformer mounted on a wheeled black steel dolly with orange and black output leads
  • Hewlett Packard 9100-4117 wiring diagram label showing dual primary shield braid and secondary shield braid windings with voltage tap configuration
  • HP 9100-4117 secondary output rating plate showing 5.0 KVA total, 120V at 41.67A and 240V at 20.83A jumper configurations with hazardous voltage warning
$500.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

HP Hewlett Packard 9100-4117 5KVA Doubly Shielded Isolation Transformer 120V

The Hewlett Packard 9100-4117 is a 5 KVA doubly shielded isolation transformer designed for use in laboratory, test, and precision electronic environments. It features both a primary shield braid and a secondary shield braid, providing two stages of electrostatic shielding between the primary and secondary windings to suppress common-mode noise and ground loops. The primary windings accept selectable input taps at 100V, 110V, or 120V, making the unit usable across a range of AC mains standards. The secondary is jumper-configurable for either 120V or 240V output.

Specifications & What's Included

  • Manufacturer: Hewlett-Packard
  • Model / Part Number: 9100-4117
  • Total Power Rating: 5.0 KVA (5000 VA)
  • Primary: Dual windings, each with taps at 0V / 100V / 110V / 120V
  • Primary Frequency: 44–66 Hz
  • Secondary: Dual windings, each 120V
  • Secondary Output — 120V configuration: 41.67A (jumpers 9-11 / 10-12)
  • Secondary Output — 240V configuration: 20.83A (jumpers 10-11 / 9-12)
  • Shielding: Doubly shielded — Primary Shield Braid and Secondary Shield Braid
  • Phase: Single phase
  • Mounting: Open-frame transformer core mounted on a wheeled black steel dolly/cart
  • Output leads present (orange and black)
  • Terminal cover box with high-voltage warning label

Applications

Doubly shielded isolation transformers like the HP 9100-4117 are standard power conditioning equipment in electronic test laboratories and precision instrument setups. The double-shield construction — a grounded electrostatic shield on both the primary and secondary sides — provides exceptional attenuation of capacitively coupled noise between the AC mains and the load, making these transformers well suited for powering sensitive test instruments, oscilloscopes, signal analyzers, and data acquisition systems where ground-loop interference and common-mode noise must be minimized. Hewlett-Packard specified and supplied these transformers as system-level accessories for their own instrument racks and test station configurations during the 1970s and 1980s, ensuring a clean, isolated AC supply for HP measurement equipment. They continue to be valued today in lab environments, audio electronics, and any application requiring high-quality AC isolation with low leakage current. The jumper-selectable secondary (120V or 240V) adds flexibility for different load requirements without rewiring.

Condition: Used
This Hewlett Packard 9100-4117 5KVA Doubly Shielded Isolation Transformer has been inspected and appears to be in good used condition. It was pulled from a working environment where it was previously in service. The transformer is mounted on a wheeled black steel dolly and shows normal wear consistent with use in a lab or industrial setting. Output leads are present and visible. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
HP
Model:
9100-4117
MPN:
9100-4117
Type:
Doubly Shielded Isolation Transformer
SKU:
32337
Power Rating:
5 KVA (5000 VA)
Primary Voltage:
100V / 110V / 120V (dual windings, selectable taps)
Secondary Voltage:
120V or 240V (jumper configurable)
Secondary Current:
41.67A @ 120V or 20.83A @ 240V
Primary Frequency:
44–66 Hz
Phase:
Single Phase
Shield Type:
Doubly Shielded — Primary Shield Braid and Secondary Shield Braid
Primary Windings:
2 (taps: 0V, 100V, 110V, 120V per winding)
Secondary Windings:
2 (120V each, configurable via jumpers)
Mounting:
Wheeled black steel dolly/cart
Country/Region of Manufacture:
United States
Form Factor:
Open Frame / Floor Unit on Wheeled Dolly
Seller Notes:
Includes transformer mounted on wheeled steel dolly with output leads.
Condition Notes:
This Hewlett Packard 9100-4117 5KVA Doubly Shielded Isolation Transformer has been inspected and is in good used condition. Pulled from a working environment. Mounted on a wheeled steel dolly. Please view photos and contact us with questions.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov