Franklin Electric

Franklin Electric 3500 Power Line Disturbance Monitor Chart Recorder 100/200V

(No reviews yet) Write a Review
SKU:
9631
MPN:
3500
Condition:
Used
Availability:
Usually ships within 1-2 business days.
Weight:
50.00 LBS
Shipping:
Calculated at Checkout
  • Franklin Electric Model 3500 Power Line Disturbance Monitor front panel view showing LED display, threshold knobs, alarm indicator, display select and monitor select switches, and chart recorder slot
  • Franklin Electric 3500 front panel close-up showing Threshold Settings knobs (Under, Over, Transient), Alarm LED, Memory Clear button, Display Select rotary switch, Monitor Select rotary switch, Clock interval selector, and Power switch
  • Franklin Electric 3500 built-in chart recorder printing a disturbance log tape — Franklin Electric Programmed Power Division logo visible on front panel
  • Franklin Electric Model 3500 printout format reference label showing Status Printout and Disturbance Printout column formats and event code legend for under voltage, over voltage, transient, and 3-phase power events
  • Franklin Electric 3500 rear panel showing three Monitor Input phase terminals with cables attached, DB-25 Monitor Output connector, multi-pin circular connectors for transient monitor and battery/chart outputs, and external connection terminals
  • Franklin Electric 3500 rear rating plate label: Model 3500, Serial 475, Volts 100/200, Amps 1A/1A, Phase 1, Hertz 50/60 — Programmed Power Division, Sunnyvale CA 94086
$250.00
Was: $500.00
Current Stock: 1

Sold Out

Description

Franklin Electric 3500 Power Line Disturbance Monitor Chart Recorder 100/200V

Benchtop power quality monitoring instrument with integrated thermal chart recorder. Monitors three-phase power lines for voltage disturbances, transients, and deviations from nominal levels.

Specifications & What's Included

  • Input: 100/200V AC, 1A single phase, 50/60Hz
  • Monitor inputs: Phase 1, Phase 2, Phase 3 (rear terminals)
  • Independently adjustable thresholds: Under, Over, Transient
  • LED numeric display with selectable readouts (voltage, phase, time, disturbance type)
  • Thermal chart recorder with 9 clock intervals from 1 second to 100 days
  • Output: DB-25 connector, status and disturbance printout with event codes
  • Includes power cables and monitor connectors

Applications

Used in industrial facilities, data centers, and telecommunications installations to log power line events and voltage anomalies over extended periods. Generates printed disturbance records for analysis and troubleshooting of power quality issues. Suitable for three-phase monitoring in 50Hz and 60Hz electrical systems.

Condition: Used
This Franklin Electric 3500 Power Line Disturbance Monitor has been inspected and appears to be in good used condition. The front panel, controls, and chart recorder mechanism all appear intact and complete based on our inspection. The unit shows light wear consistent with previous bench or facility use — the cabinet has some minor scuffing and the front panel shows typical handling marks, but there is no significant damage visible. The rear phase input cables are present as shown in the photos. The rating plate is fully legible: 100/200V, 1A/1A, Single Phase, 50/60Hz. This unit was pulled from a working environment. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Franklin Electric
Model:
3500
MPN:
3500
Type:
Power Line Disturbance Monitor with Chart Recorder
SKU:
9631
Seller Notes:
Unit includes built-in thermal chart recorder and power/monitor cables visible in photos.
Country/Region of Manufacture:
United States
Form Factor:
Benchtop
Power Requirements:
100/200V AC, 1A/1A, Single Phase, 50/60Hz
Voltage Rating:
100/200V
Current Rating:
1A / 1A
Phase:
Single Phase (1Ø)
Frequency:
50/60 Hz
Measurement Type:
Power Line Disturbance / Power Quality
Monitor Inputs:
Phase 1, Phase 2, Phase 3 (3 monitor input terminals, rear)
Threshold Settings:
Under, Over, and Transient — independently adjustable
Display Type:
LED numeric display + built-in thermal chart recorder
Display Select:
Transient, Over, Under, Phase 1, Phase 2, Phase 3, Time
Monitor Select:
Phase 1, Phase 2, Phase 3, All Phases, 3-Phase Power
Clock Intervals:
1 Hr, 10 Hr, 1 Day, 10 Day, 100 Day; 10 Min, 1 Min, 10 Sec, 1 Sec, Run
Printout Format:
Status Printout and Disturbance Printout with event codes
Rear Connectors:
DB-25 Monitor Output, multi-pin circular connectors, input terminals
Manufacturer Division:
Franklin Electric — Programmed Power Division, Sunnyvale CA
Condition:
Used – Inspected, Pulled from Working Environment
Condition Notes:
Franklin Electric 3500 Power Line Disturbance Monitor in good used condition. Shows light handling wear; cabinet and controls intact. Rear phase cables present. Pulled from a working environment.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov
View AllClose