Fluke

Fluke 8050A Digital Multimeter For Parts Bad Display AS-IS Benchtop DMM

(No reviews yet) Write a Review
SKU:
45935
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
3.00 LBS
Shipping:
Calculated at Checkout
  • Fluke 8050A digital multimeter front view showing LCD display, function buttons, input jacks, and tilt stand on bench
  • Fluke 8050A digital multimeter rear view showing AC power inlet, voltage selector switch, and red AS-IS label
  • Fluke 8050A operator's guide summary specification label on underside showing accuracy, ranges, power requirements, and operating notes
  • Fluke 8050A digital multimeter front panel showing range buttons, AC/DC selector, mA and voltage input jacks, REF Z, MIN/MAX, and Relative controls
  • Fluke 8050A front panel close-up showing input jacks labeled COMMON and V/kΩ/S, POWER button, RELATIVE switch, and Calibration ID label 0461
  • Fluke 8050A LCD display close-up showing '-18. dB' reading — display is partially functional but defective
$45.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Fluke 8050A Digital Multimeter For Parts Bad Display AS-IS Benchtop DMM

The Fluke 8050A is a 4.5-digit true RMS benchtop digital multimeter capable of measuring AC and DC voltage, AC and DC current, resistance, conductance, and dBm. This unit is being sold AS-IS due to a defective LCD display. As shown in the close-up photo, the display produces a partial reading but is not functioning normally. All other front-panel controls, input jacks, and the tilt stand are physically intact.

Specifications & What's Included

  • Manufacturer: Fluke (John Fluke Mfg. Co., Everett, WA, USA)
  • Model: 8050A
  • Type: 4.5-digit true RMS benchtop digital multimeter
  • DC Voltage: 200mV to 1000V, accuracy ±(0.03% + 1 digit) on best range
  • AC Voltage (True RMS): 200mV to 750V, 20Hz–50kHz
  • DC Current: 200µA to 2A
  • AC Current (True RMS): 200µA to 2A
  • Resistance: 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ
  • Conductance: 2mS, 200mS
  • dBm range: –52 dBm to +57 dBm (referenced to 600Ω)
  • Features: REF Z, MIN/MAX capture, Relative mode, dB, diode test, S=1/Ω
  • Input jacks: COMMON, mA (2A/250V fused), V/kΩ/S (500V DC / 750V AC / 1000V DC max)
  • Power: 120V AC primary (switchable 100/220/240V), 47–440Hz, 6W max; internal battery option
  • Display: 4.5-digit LCD — DEFECTIVE (sold for parts/repair)
  • Calibration ID label: 0461
  • Included: Unit with tilt stand — no test leads or accessories

Applications

The Fluke 8050A was introduced in the early 1980s and became a standard benchtop DMM in electronics labs, service shops, and calibration facilities. Its true RMS measurement capability made it more accurate than average-responding meters for non-sinusoidal waveforms, and its dBm function was useful for audio and RF-level work. The 8050A was built to a high standard of reliability and many units remain in service decades later. This example, with a defective display, is well suited as a parts source for another 8050A needing components, or as a repair project for technicians familiar with the instrument. The LCD module, input switching network, power supply section, and front-panel hardware are all potential sources of usable parts.

Condition: For Parts or Not Working
This Fluke 8050A Digital Multimeter is being sold AS-IS due to a bad display. As shown in the close-up photo, the LCD is partially functional but defective — not suitable for normal use. The unit is otherwise complete with its tilt stand and all front-panel controls and input jacks intact. The case shows general wear consistent with lab use. It is not tested beyond what is visible and is not guaranteed functional. Sold for parts or repair only. Please view our photo set and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Fluke
Model:
8050A
MPN:
8050A
Type:
Digital Multimeter (DMM)
SKU:
45935
Seller Notes:
Unit only — no test leads or accessories visible.
Country/Region of Manufacture:
United States
Form Factor:
Benchtop
Power Requirements:
120V AC (switchable 100/220/240V), 47-440 Hz, 6W max; battery option
Measurement Functions:
AC/DC Voltage, AC/DC Current, Resistance, Conductance, dBm, Relative
True RMS:
Yes
DC Voltage Accuracy:
±0.03% + 1 digit (best range)
Voltage Range:
200mV to 1000V DC; 200mV to 750V AC
Current Range:
200µA to 2A
Resistance Range:
200Ω to 20MΩ
Conductance Range:
2mS, 200mS
dBm Range:
-52 dBm to +57 dBm
Display:
4.5-digit LCD (display defective — sold for parts)
Fuse:
2A, 250V (internal)
Features:
REF Z, MIN/MAX, Relative, dB, S=1/Ω, Diode Test
Calibration ID:
0461 (label visible on front panel)
Condition Notes:
This Fluke 8050A Digital Multimeter is sold AS-IS for parts or repair due to a bad/defective LCD display. Unit is otherwise complete with tilt stand and all controls. Not tested, not guaranteed functional.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov