Esterline Angus

Esterline Angus A6106 Graphic Voltmeter Chart Recorder 90-130VAC Style 190M

(No reviews yet) Write a Review
SKU:
35773
MPN:
A6106
Condition:
Used
Availability:
Currently out of stock — contact us for availability.
Weight:
38.00 LBS
Shipping:
Calculated at Checkout
  • Esterline Angus A6106 graphic voltmeter chart recorder front view showing circular chart paper and Esterline Angus logo badge, with power cord
  • Esterline Angus A6106 chart recorder rear view showing vented enclosure and carrying handle
  • Esterline Angus Graphic Voltmeter nameplate close-up showing instrument label and pen arm assembly over circular chart paper
  • Esterline Angus chart drive module close-up showing Chart Drive nameplate with style and voltage markings, speed knob, and circular chart paper
  • Esterline Angus chart recorder side panel detail showing two red thumbwheel knobs and Minute/Off/Hour speed selector toggle switch
  • Esterline Angus A6106 chart recorder front close-up showing Esterline Angus logo badge and circular grid chart paper through front opening
  • Esterline Angus A6106 top panel showing severely cracked glass window over voltage scale display with pen arm latch visible
  • Esterline Angus A6106 chart recorder shown with enclosure cover removed, exposing internal chassis and rear terminal panel with three input terminal knobs
  • Esterline Angus A6106 rear input terminal panel close-up showing 260V and 130V terminal knobs and shock hazard warning label
$107.00
Was: $180.00

This item is temporarily unavailable. Please view our recommended, in-stock alternatives directly below.

Description

Esterline Angus A6106 Graphic Voltmeter Chart Recorder 90-130VAC Style 190M

The Esterline Angus A6106 is a circular-drum graphic voltmeter chart recorder, Style 190M, designed to continuously record voltage levels over time on a circular paper chart. It operates on 90–130VAC, 60Hz and accepts input with 1V resolution. The chart drive runs at selectable per-hour and per-minute speeds, switched via a front-side toggle. This unit is being sold AS-IS for parts or repair due to a missing recording pen and a severely cracked top glass window.

Specifications & What's Included

  • Manufacturer: Esterline Angus, Indianapolis, Indiana, USA
  • Model / Part Number: A6106
  • Style: 190M
  • Input Voltage: 90–130VAC
  • Power: 120V, 60Hz
  • Voltage Resolution: 1V
  • Chart Type: Circular drum chart
  • Chart Drive Speeds: Per minute / Per hour (toggle switchable)
  • Input Terminals: Three terminal knobs on rear panel (260V and 130V positions visible)
  • Rear panel: Shock hazard warning label — terminals must be covered before connecting signal leads
  • Side controls: Two red thumbwheel knobs and Minute/Off/Hour speed selector toggle
  • Enclosure: Gray painted steel with fold-down metal carrying handle
  • Circular chart paper is present in the unit
  • Known issues: Recording pen is missing; top glass window is cracked and shattered
  • Sold AS-IS — no pen, no warranty, no guarantee of full functionality

Applications

Esterline Angus graphic voltmeter chart recorders were standard instruments in industrial, utility, and laboratory settings for continuous voltage monitoring and data logging. The circular chart format allowed unattended recording over extended periods — typically 24 hours per revolution on the hourly setting — making them well suited for power quality monitoring, process control verification, and regulatory compliance documentation in electrical substations, manufacturing plants, and test labs. Esterline Angus (later part of Danaher) was a well-regarded American manufacturer of strip and circular chart recorders from the mid-20th century onward. This style of analog chart recorder dates from roughly the 1960s–1980s era, when pen-and-paper circular recorders were the dominant continuous-logging technology before digital data acquisition systems became widely available. Today these instruments are sought by collectors of vintage test equipment, hobbyists, and technicians needing replacement parts or a chassis for restoration projects.

Condition: For Parts or Not Working
This Esterline Angus A6106 Graphic Voltmeter Chart Recorder (Style 190M) is being sold AS-IS for parts or repair. The recording pen is missing, and the top glass window is visibly cracked and shattered. The paper feed mechanism does run — the chart drive operates on both the per-hour and per-minute speed settings — but the unit is sold without any functionality guarantee and is not warranted as working. The rear input terminal panel shows three terminal knobs (260V and 130V positions visible) with a shock hazard warning label. The enclosure is gray painted steel with a fold-down carrying handle and shows wear consistent with age and lab use. Please review our full photo set carefully before purchasing, and contact us if you have any questions.
View AllClose

Warranty Information

We stand behind every item we sell with a 30-day money-back guarantee. If your item arrives not as described, you may return it within 30 days for a full refund. Please inspect your purchase upon arrival and contact us with any questions.
View AllClose

Additional Information

Brand:
Esterline Angus
Model:
A6106
MPN:
A6106
Secondary Model:
Style 190M
Type:
Circular Chart Recorder / Graphic Voltmeter
SKU:
35773
Voltage:
90-130VAC
Power Requirements:
120V 60Hz
Voltage Range (Input):
1V Resolution
Chart Speed:
Per hour and per minute (switchable)
Chart Type:
Circular / Drum
Country/Region of Manufacture:
United States
Form Factor:
Portable / Benchtop
Seller Notes:
Recorder only — no pen included; paper chart present in unit
Known Issues:
Recording pen missing; top glass window cracked
Condition Notes:
Esterline Angus A6106 Chart Recorder sold AS-IS for parts or repair. Pen missing, top glass window cracked/shattered. Paper feed motor runs on both speed settings. Not guaranteed functional. No warranty.
California Prop 65 Warning:
WARNING: This product can expose you to chemicals including lead and lead compounds, and DEHP (a phthalate), which are known to the State of California to cause cancer and birth defects or other reproductive harm. Go to P65Warnings.ca.gov
View AllClose