Ventronics
-
Ventronics 5576 Polarographic Monitor Oxygen Analysis Measurement
Ventronics
$75.00Was: $150.00Ventronics 5576 Polarographic Monitor Oxygen Analysis MeasurementThe Ventronics 5576 is a polarographic oxygen monitor designed for precise measurement and monitoring of oxygen levels (pO2 — partial...11396- SKU:
- 11396
- Availability:
- Usually ships within 1-2 business days.
- Weight:
- 0.00 LBS
- Brand:
- Ventronics
- Model:
- 5576
- Type:
- Polarographic Oxygen Monitor
- SKU:
- 11396
- Measurement Type:
- Oxygen / pO2 (partial pressure)
- Application:
- Medical gas analysis, respiratory monitoring, laboratory oxygen measurement
- Sensor Type:
- Polarographic cell (not included with this unit)
- Seller Notes:
- Unit sold without sensor. Contact us for sensor compatibility details.
- Condition:
- Used – Inspected
- Condition Notes:
- Ventronics 5576 polarographic oxygen monitor in good used condition. Sensor not included. Visually inspected. Contact us for sensor compatibility information before purchasing.
$75.00Was: $150.00 -
Ventronics 5571 Polarographic Monitor Medical Lab Analyzer Oxygen
Ventronics
$100.00Was: $200.00Ventronics 5571 Polarographic Monitor Medical Lab Analyzer OxygenThe Ventronics 5571 is a benchtop polarographic monitor designed for measurement of dissolved oxygen and oxygen partial pressure in...11399- SKU:
- 11399
- Availability:
- Usually ships within 1-2 business days.
- Weight:
- 0.00 LBS
- Brand:
- Ventronics
- Model:
- 5571
- Type:
- Polarographic Monitor / Oxygen Analyzer
- SKU:
- 11399
- Application:
- Medical Laboratory / Oxygen Analysis
- Measurement Type:
- Dissolved Oxygen / Oxygen Partial Pressure
- Sensor Type:
- Polarographic (sensor not included)
- Condition:
- Used
- Country/Region of Manufacture:
- USA
- Condition Notes:
- Ventronics 5571 Polarographic Monitor in used condition. Unit has been inspected and is ready for use in a laboratory or medical setting. Sensor not included. Please contact us with any questions before purchasing.
$100.00Was: $200.00 -
Ventronics 5528 Digital Oxygen Monitor Galvanic Sensor Model 5510 For Parts
Ventronics
$50.00Was: $100.00Ventronics 5528 Digital Oxygen Monitor Galvanic Sensor Model 5510 For PartsThe Ventronics Model 5528 is a portable benchtop digital oxygen monitor designed to measure and display ambient percent...21561- SKU:
- 21561
- Availability:
- Usually ships within 1-2 business days.
- Weight:
- 6.00 LBS
- Brand:
- Ventronics
- Model:
- 5528
- MPN:
- 5528
- Type:
- Digital Oxygen Monitor
- SKU:
- 21561
- Condition:
- As-Is / For Parts or Not Working
- Seller Notes:
- No sensor included. Requires Model 5510 galvanic sensor. Sold as-is.
- Country/Region of Manufacture:
- United States
- Form Factor:
- Benchtop / Portable
- Sensor Type:
- Galvanic (Model 5510 sensor required, not included)
- Measurement Type:
- Percent Oxygen (%O2)
- Alarm Type:
- Audio alarm with Low and High thumbwheel alarm settings
- Display Type:
- Digital LCD — Percent Oxygen readout
- Connector Type:
- Multi-pin edge/card connector (sensor port)
- Power Source:
- Battery (battery compartment visible on rear)
- Compatible Sensor:
- Ventronics Model 5510 Galvanic Sensor
- Controls:
- Calibrate knob, Audio Alarm Silence, ON/OFF toggle, Low/High alarm thumbwheels
- Manufacturer Division:
- Ventronics, Division of Hudson, Temecula, CA
- Application:
- Oxygen level monitoring with alarm, medical/industrial environments
- Condition Notes:
- Ventronics 5528 Digital Oxygen Monitor sold as-is for parts or repair. Cannot be tested; no sensor included (requires Model 5510). Internal batteries likely depleted. Cosmetically intact with light wear. Please contact us with questions.
$50.00Was: $100.00 -
Ventronics 5570 Polarographic Oxygen Monitor No O2 Sensor Parts Repair
Ventronics
$35.00Was: $70.00Ventronics 5570 Polarographic Oxygen Monitor No O2 Sensor Parts RepairBenchtop polarographic oxygen monitor designed to measure and display percent oxygen (%O2) levels. Features LCD readout with...21562- SKU:
- 21562
- Availability:
- Usually ships within 1-2 business days.
- Weight:
- 6.00 LBS
- Brand:
- Ventronics
- Model:
- 5570
- MPN:
- 5570
- Type:
- Polarographic Oxygen Monitor
- SKU:
- 21562
- Condition:
- As-Is / For Parts or Not Working
- Seller Notes:
- No O2 sensor included. Comes in original box with manual.
- Compatible Sensor:
- Ventronics Model 5580 Polarographic Sensor
- Display Type:
- LCD (Percent Oxygen readout)
- Alarm Settings:
- Low and High thumbwheel switches on front panel
- Sensor Interface:
- Multi-pin connector (Polarographic Sensor Only port)
- Measurement Type:
- Percent Oxygen (%O2)
- Form Factor:
- Benchtop
- Dimensions:
- 8" x 5" x 6"
- Country/Region of Manufacture:
- United States
- Manufacturer Location:
- Temecula, CA 92390
- Division:
- Ventronics Division of Hudson
- Condition Notes:
- Ventronics 5570 Polarographic Oxygen Monitor sold as-is for parts or repair. We could not fully test it. No O2 sensor included. Comes in original box with manual. Not guaranteed functional.
$35.00Was: $70.00 -
Ventronics 5529 Digital Oxygen Analyzer Hudson Galvanic Sensor Port For Parts
Ventronics
$35.00Was: $70.00Ventronics 5529 Digital Oxygen Analyzer Hudson Galvanic Sensor Port For PartsPortable digital oxygen analyzer designed to measure oxygen concentration in respiratory and medical gas applications...21564- SKU:
- 21564
- Availability:
- Usually ships within 1-2 business days.
- Weight:
- 6.00 LBS
- Brand:
- Ventronics
- Model:
- 5529
- MPN:
- 5529
- Type:
- Digital Oxygen Analyzer
- SKU:
- 21564
- Condition:
- As-Is / For Parts or Not Working
- Seller Notes:
- Includes original box and operating manual. Model 5510 sensor NOT included.
- Compatible Sensor:
- Model 5510 Galvanic Oxygen Sensor (not included)
- Sensor Port Type:
- Galvanic Sensor Only (multi-pin connector)
- Display Type:
- LCD — Percent Oxygen readout
- Measurement Parameter:
- Percent Oxygen (%O2)
- Calibration:
- Manual calibration knob; calibrate against 100% O2
- Battery Indicator:
- Low battery display (LO BAT) at 90% battery depletion
- Form Factor:
- Portable / Handheld with carry handle
- Manufacturer Division:
- Ventronics, Division of Hudson, Temecula CA 92390
- Includes:
- Unit, original foam-padded box, operating manual
- Country/Region of Manufacture:
- United States
- Application / Use Case:
- Oxygen concentration measurement, medical/respiratory gas analysis
- Condition Notes:
- Ventronics 5529 Digital Oxygen Analyzer sold AS-IS for parts or repair. Untested. Model 5510 galvanic sensor not included. Comes in original foam box with operating manual. No functionality guaranteed.
$35.00Was: $70.00