Beckman Model 25 UV-VIS Spectrophotometer 190-900nm 115V Dual Source PMT Lab
The Beckman Model 25 is a benchtop single-beam UV-VIS spectrophotometer designed for quantitative laboratory analysis across the ultraviolet and visible light spectrum. It measures absorbance and concentration of liquid samples in cuvettes, covering a wavelength range of 190 to 900 nm. The instrument features a digital LED absorbance readout, a numerical wavelength display, front-panel baseline adjustment and concentration calibration controls, and a dual-position sample compartment with separate reference (R) and sample (S) cuvette holders.
Specifications & What's Included
- Make: Beckman
- Model: Model 25 Spectrophotometer
- Wavelength Range: 190–900 nm
- Power: 115V AC, 2.2A
- Light Sources: Deuterium lamp (UV range) and incandescent lamp (visible range) — UV/VISIBLE selector switch on top panel
- Detector: Photomultiplier tube (PMT) — assumed; type not confirmed
- Absorbance Display: Red LED digital readout
- Wavelength Display: Digital numerical readout
- Operating Modes: Absorbance (ABS), Concentration (CONC), Idle — front-panel pushbutton selection
- Baseline Adjust: Front-panel rotary knob
- Concentration Calibration: Front-panel rotary knob (CONC. CALIB.)
- Sample Compartment: Dual position — Reference (R) and Sample (S) cuvette holders
- Microcell Aperture: MICRO/STD toggle selector for use with standard or micro cuvettes
- Form Factor: Benchtop
- Condition Note: Visible crack/separation in top housing panel near UV/VISIBLE selector switch
- Calibration Label: Expired April 2003 (procedure 5.18, calibrated 10/3/02) — recalibration required
- Included: Instrument only — no cuvettes, manual, or accessories
Applications
The Beckman Model 25 was a widely used workhorse UV-VIS spectrophotometer in academic, industrial, and clinical laboratories from the 1970s through the 1990s. It is suited for routine quantitative analysis tasks: measuring DNA and protein concentration by absorbance at 260 nm and 280 nm, enzyme kinetics, colorimetric assays, and general solution concentration measurements. The 190–900 nm range covers the full UV and visible spectrum, making it versatile for a broad range of chemical and biological applications. Instruments of this generation are commonly found in teaching labs, quality control environments, and smaller research settings where a reliable, straightforward single-beam spectrophotometer is preferred over more complex modern instruments. Spare deuterium and incandescent lamps as well as compatible cuvettes are widely available, supporting continued use and maintenance of this model.
This Beckman Model 25 UV-VIS Spectrophotometer has been pulled from a working laboratory environment. Photos show the unit powered on and displaying live absorbance and wavelength readings (2.781 absorbance at 279 nm in one photo, with a separate view at 990 nm), suggesting the instrument was operational at time of photography — however, it has not been formally bench-tested at our facility and is sold without a functionality guarantee. The sample compartment interior is clean with both reference (R) and sample (S) cuvette holders present. The top housing panel shows a visible crack/separation near the UV/VISIBLE source selector switch on the rear-top surface. The instrument carries an expired calibration label (procedure 5.18, calibrated 10/3/02, expired April 2003) — recalibration will be needed before use in a certified application. The detector type was not confirmed; a photomultiplier tube (PMT) is assumed based on the instrument design. Please review all photos carefully and contact us with any questions before purchasing.
Warranty Information
Additional Information
Brand: |
Beckman |
Model: |
Model 25 |
MPN: |
Model 25 |
Type: |
UV-VIS Spectrophotometer |
SKU: |
24170 |
Wavelength Range: |
190-900 nm |
Light Sources: |
Deuterium (UV) and Incandescent (Visible) |
Detector: |
Photomultiplier Tube (PMT) — assumed |
Power Requirements: |
115V AC, 2.2A |
Display Type: |
Red LED digital readout (absorbance/concentration) |
Wavelength Display: |
Digital numerical wavelength readout |
Microcell Aperture: |
Yes — MICRO/STD selector switch |
Sample Configuration: |
Dual position: Reference (R) and Sample (S) |
Form Factor: |
Benchtop |
Baseline Adjust: |
Front-panel rotary knob |
Concentration Calibration: |
Front-panel rotary knob (CONC. CALIB.) |
Country/Region of Manufacture: |
United States |
Compatible With: |
Standard 1cm cuvettes; microcells with aperture adapter |
Seller Notes: |
Unit only — no cuvettes, cables, or manual included. |
Condition Notes: |
Beckman Model 25 UV-VIS Spectrophotometer pulled from a working lab. Photos show unit powered on with live readings. Not formally bench-tested; sold as-is. Crack visible in top housing panel. Calibration expired April 2003. PMT detector assumed. |
California Prop 65 Warning: |