Description
APC AP7862 42-Outlet Metered Rackmount PDU 120/208V 3-Phase NEMA L21-20P
The APC AP7862 is a 0U vertical metered rackmount power distribution unit designed for deployment in server rooms and data centers. It accepts a single 3-phase NEMA L21-20P input at 120/208V AC and distributes power across 42 individually numbered NEMA 5-20R outlets, with outlets balanced across three phases (L1, L2, L3). A built-in digital amp meter and per-phase LED indicators let rack administrators monitor current draw at a glance without additional metering equipment.
Specifications & What's Included
- Model: APC AP7862
- Type: 0U Vertical Metered Rackmount PDU
- Number of Outlets: 42 × NEMA 5-20R (120V output), numbered and phase-labeled
- Input Plug: NEMA L21-20P (3-phase locking plug)
- Input Voltage: 120/208V AC, 3-Phase
- Input Current Rating: 20A
- Frequency: 50/60 Hz
- Metering: Per-phase digital amp display (L1, L2, L3 selectable); OK / Warning / Overload LED indicators
- Network Management Interface: 10/100 Ethernet (RJ-45)
- Serial Port: RJ-45 serial management port
- Reset button on control panel
- Form Factor: 0U — mounts vertically inside standard 19" rack enclosure
- Country of Manufacture: India (per label)
- Includes: PDU with attached input cord only — no mounting hardware or documentation
Applications
The AP7862 is part of APC's Metered Rack PDU line, designed for high-density server racks and network enclosures in data centers, colocation facilities, and enterprise IT rooms. The 3-phase input configuration distributes load evenly across phases, which is standard practice in larger rack deployments to balance electrical load on the facility's distribution system. The per-phase amp metering allows IT staff to monitor utilization and prevent tripping circuit breakers from overload — a critical function in dense rack environments. The 10/100 Ethernet and serial management ports support remote monitoring when connected to APC's network management infrastructure. With 42 outlets on a single 0U vertical unit, this PDU is well suited for high-outlet-count racks housing 1U and 2U servers, switches, and patch panels.
Note: Due to the length of this item, standard shipping rates calculated by weight do not apply. Please contact us before ordering to confirm the shipping cost to your location.
This APC AP7862 42-Outlet Metered Rackmount PDU has been inspected and appears to be in good used condition. It was pulled from a working data center environment where it was previously in use. The outlets, control panel, and input cord all appear intact with no obvious damage visible in the photos. Normal scuffing and handling wear typical of used rack-mounted equipment may be present. Because of its length, standard shipping rates do not apply — please contact us before purchasing to confirm the shipping cost to your location. Please view our photo set and contact us if you have any questions.
Warranty Information
Additional Information
Brand: |
APC |
Model: |
AP7862 |
MPN: |
AP7862 |
Type: |
Metered Rackmount PDU (Power Distribution Unit) |
SKU: |
40435 |
Number of Outlets: |
42 |
Input Voltage: |
120/208V AC |
Input Plug Type: |
NEMA L21-20P |
Input Current Rating: |
20A |
Phase: |
3-Phase |
Output Voltage: |
120V AC |
Output Connector Type: |
NEMA 5-20R |
Frequency: |
50/60 Hz |
Metering: |
Per-phase amp metering with LED display |
Management Type: |
Metered (local display); 10/100 Ethernet + Serial port |
Network Interface: |
10/100 Ethernet (RJ-45), Serial port (RJ-45) |
Form Factor: |
Rackmount — 0U Vertical |
Seller Notes: |
PDU only — no mounting hardware or documentation included. |
Country/Region of Manufacture: |
India |
Compatible With: |
Standard 19" server racks and enclosures |
Power Requirements: |
NEMA L21-20P, 120/208V AC, 3-Phase, 20A, 50/60Hz |
Condition Notes: |
This APC AP7862 42-Outlet Metered Rackmount PDU is in good used condition, pulled from a working data center environment. Outlets and cord appear intact. Contact us for oversized shipping rate. |